SRP 003-304 • Issue 9 • July 2004

2.3

The EDC will hold up to three Type 2R

0.2-inch high or two Type 4R 0.4-inch high
reduced length splice trays (ordered separately).

2.4

The unit can be field connectorized using

Corning Cable Systems Buffer Tube Fan-out
(BTF) kits, which are ordered separately.

2.5

The EDC comes with brackets to mount

the unit to a wall or a standard utility pole. The
unit may be rack-mounted with an optional
rack-mount kit (purchased separately).

2.6

The unit may be pad-locked with a user-

supplied padlock after installation of the
provided quick-release latch kit.

2.7

Factory stubbed units are available with a

preconnectorized length of fiber optic cable
installed and strain-relieved inside the unit.

3.

Precautions

3.1

Laser Handling Precautions

WARNING:

 

Never look directly into the

end of a fiber that may be carrying laser light.

Laser light may be invisible and can damage your eyes.
Viewing it directly does not cause pain. The iris of the
eye will not close involuntarily as when viewing a
bright light. Consequently, serious damage to the
retina of the eye is possible. Should accidental eye
exposure to laser light be suspected, arrange for an eye
examination immediately.

WARNING:

 DO NOT use magnifiers in the

presence of laser radiation. Diffused laser light can
cause eye damage if focused with optical instruments.
Should accidental eye exposure be suspected, arrange
for an eye exam immediately.

3.2

Safety Precautions

CAUTION:

 The wearing of safety glasses to

protect the eyes from accidental injury is strongly
recommended when handling chemicals and cutting
fiber. Pieces of glass fiber are very sharp and can
damage the cornea easily.

CAUTION:

The wearing of safety gloves to

protect hands from accidental injury is strongly
recommended when using sharp instruments.

CAUTION

Isopropyl alcohol is flammable

with a flashpoint at 50

°

F. It can cause irritation to

eyes on contact. In case of eye contact, flush eyes with
water for at least 15 minutes. Inhaling fumes may
induce mild narcosis. In case of ingestion, consult a
physician.

CAUTION: 

The filling compound remover

used to clean loose-tube cable contains petroleum
distillates which are harmful or fatal if swallowed.
DO NOT induce vomiting. Call physician
immediately.

3.3

Glass Fiber Precautions

WARNING: 

Cleaved glass fibers are very

sharp and can pierce the skin easily. Do not let cut

pieces of fiber stick to your clothing or drop in the work
area where they can cause injury later. Use tweezers to
pick up cut or broken pieces of the glass fibers and place
them on a loop of tape kept for that purpose alone.

Good housekeeping is very important.

3.4

Cable Handling Precautions

NOTE: 

Fiber optic cable is sensitive to excessive

pulling, bending and crushing forces. Consult the cable
specification sheet for the cable you are installing. 

Do

not bend cable more sharply than the minimum
recommended bend radius. Do not apply more
pulling force to the cable than specified. Do not
crush the cable or allow it to kink.

 Doing so may

cause damage that can alter the transmission
characteristics of the cable — the cable may have to be
replaced.

3.5

Installer Precautions

WARNING:

 Do not install this unit or work

with telephone wiring during a lightning storm.

Telephone lines can carry high voltages from lightning
causing electrical shock resulting in severe injury or
death.

Содержание EDC-02P-NH

Страница 1: ...ctions NOTE Read and understand this procedure as well as the instructions provided with related assemblies before beginning an installation Make sure you know how the unit will be mounted and how the distribution cable and drop cable will be routed to the unit 2 Description 2 1 The EDC is a cabinet designed for storage and protection of fiber optic connections and splices in an outdoor environmen...

Страница 2: ...micals and cutting fiber Pieces of glass fiber are very sharp and can damage the cornea easily CAUTION The wearing of safety gloves to protect hands from accidental injury is strongly recommended when using sharp instruments CAUTION Isopropyl alcohol is flammable with a flashpoint at 50 F It can cause irritation to eyes on contact In case of eye contact flush eyes with water for at least 15 minute...

Страница 3: ...x wrench Utility pole or wall mounting hardware as required by your installation Two cable entry port fittings ordered separately and sealant if required 5 Components 5 1 Components are illustrated in Figure 2 The base plate is the dark metal plate that holds the components inside the enclosure It is secured by four screws 5 2 An installation kit is provided that includes cable ties central member...

Страница 4: ...ets 8 1 When wall mounting a Remove the stabilizer bracket Figure 4 b Drive 1 4 inch screws or wall anchors through the stabilizer bracket and into the mounting surface Do not install a screw in the bottom hole of the stabilizer bracket at this time c Hang the unit on the stabilizer bracket ensuring that the top mounting bracket is resting between the two tabs on the stabilizer bracket Figure 5 8 ...

Страница 5: ...on the left at the base of the unit 9 2 Perform cable sheath removal steps per instructions for the type of cable being installed Cut the cable to 2 meters 6 feet inside the unit NOTE Do not expose the bare fiber until you are ready to terminate it 9 3 Install a sheath retention clamp onto the cable sheath as illustrated in Figure 6 If an armored cable is used install the ground clamp before insta...

Страница 6: ... nut c Insert the central member of the cable between the bracket and the U shaped washer d Arrange the buffer tubes to ensure clearance around the central member clamp assembly and hardware e Tighten the hex nut f Install the two flat washers g Loosely install the other hex nut h Wrap the strength member yarn in a clockwise direction around the bolt and between the flat washers i Tighten the seco...

Страница 7: ...he connector panels into the connector support bracket Figure 14 10 Connector Panels 10 1 LANscape connector panels Figure 12 are sold separately typically with connector adapters installed 10 2 If fibers are not already connectorized install connectors onto the fibers using pigtail splicing or direct connectorization per manufacturer s instructions If installing BTF kits proceed to Section 12 10 ...

Страница 8: ...ons provided with the splice trays to determine the appropriate length of fiber required in the tray Measure from the first mark towards the end of the cable and mark the cable This is the fiber that will be routed inside the splice tray f Trim the excess buffer tube beyond the second mark g Remove the splice tray and the coiled buffer tubes h Strip the buffer tube from the fibers from the mark yo...

Страница 9: ...ius to the connector panel 11 7 Secure the splice tray to the wall as shown in Figure 18 Discard spacers as required for the type of tray installed 12 Installing BTF Kits 12 1 Fiber optic cable can be installed using Corning Cable Systems BTF kits 12 2 Route the buffer tubes twice around the radius guides in a counterclockwise direction Mark the location of the mounting bracket on the buffer tubes...

Страница 10: ...ius guides 13 2 If the drop cables do not include central members secure the cables to the bracket using a loosely tightened cable tie When central member strain relief is necessary remove the drop cable strain relief bracket and secure the cable to the bracket using a cable tie as shown Figure 22 a Install the 8 32x5 8 screw from the front side of the strain relief bracket through the flat washer...

Страница 11: ... fiber optic cable to make sure bends do not exceed the minimum bend radius Check cable for unnecessary strain Check cable entries and exits for crimping or crushing Documentation Check record label to make sure it is clear and accurate 15 Specifications The unit weighs 4 3 kg 10 lb f Trim off the excess yarn and central member g Reinstall the strain relief bracket NOTE The exposed length of the c...

Страница 12: ...s are the properties of their respective owners Corning Cable Systems is ISO 9001 certified 2000 2004 Corning Cable Systems All rights reserved Published in the USA p n 003 304 July 2004 Customer Service and Information Telephone Customer Service US or Canada 1 800 743 2671 International 1 828 901 5000 Fax 1 828 325 5060 Correspondence Corning Cable Systems LLC PO Box 489 Hickory NC 28603 0489 USA...

Отзывы: