Viper Installation Manual
© 2010-2016, Cornelius Inc.
- 25 -
Publication Number: 621360041TBINS
Figure 22.
4
Manually press the water valve at the front of the unit (Figure 19.) in the mid-
dle of the water flow regulator to clean out the sample tube and close the
valve at end of the sample tube.
5
Once the BRIX is properly set, turn the product supply valve to the upright
(Product) position for the barrel you are testing. (See Figure 21.)
6
From the Barrel Maintenance menu, press the PURGE button to fill the bar-
rel with CO
2
.
7
Bleed the air from the face plate relief valves for 30 seconds each to remove
air from the barrels.
8
Go to the Barrel Maintenance menu and press FILL to fill the barrel.
9
Fill the barrel by opening up the barrel faceplate relief valve for the barrel
(See Figure 23.). Fill the barrel to the level shown in Figure 23. (approx. half
way between the relief valve and the top of the barrel) for 20-25% overrun.
10
After finishing BRIX testing and adjustment for the first barrel, repeat this
procedure for each of the other barrels, as required.
11
When BRIX adjustments are complete and all the air is purged from the sys-
tem, replace the splash panel.
NOTE: If any of the valve covers were removed during the
process, make sure to replace them.
Table 17.
Step
Action
Syrup Flow
Control Knob
Water Flow
Control Knob
(Do Not Adjust)