Viper Installation Manual
Publication Number: 621360041TBINS
- 24 -
© 2010-2016, Cornelius Inc.
Figure 21.
Adjusting BRIX Level
If the BRIX reading is out of its proper range, the syrup level should be adjusted to bring BRIX into the proper
range. NEVER change the WATER FLOW CONTROL setting to adjust BRIX. The syrup flow control adjustment
valve is shown in Figure 22. Perform the procedure in Table 17.
8
Open the valve at the end of the sample tube. Press the BRIX button. The
product pump will pump product for approximately 3 seconds. After the
sample is dispensed Press the BRIX button twice more to dispense product
two more times. Discard all three of these samples.
9
Press the BRIX button again. Collect a sample from the cup.
10
Place adequate amount of the sample on a refractometer and read the
BRIX value. A target BRIX reading of
12.2 (+/- 0.2)
is normally desired for
sugar-based syrups. Lower values for some diet syrups can be specified.
Check with the syrup manufacturer if you are not sure.
11
If BRIX level needs to be adjusted, perform the Adjusting BRIX Level proce-
dure in Table 17.
12
Repeat this procedure for each barrel in the system.
13
Replace splash panel on unit.
Table 17.
Step
Action
1
Remove the drip tray and the access panel behind it, if not already removed.
2
To increase the BRIX reading, turn the syrup flow control knob clockwise.
Turn it counter-clockwise to decrease the BRIX reading. Never adjust the
flow control more than 1/2-turn at a time.
3
Repeat steps 7 through 10 of Table 16. for each adjustment until the proper
BRIX setting is achieved.
Table 16.
Step
Action
Product
Supply
Valve
Barrel 1
Product
Supply
Valve
Barrel 3
Valves shown in Product position w/ Splash Panel Removed
Product
Supply
Valve
Barrel 2