background image

6

620906904

START-UP AND OPERATING INSTRUCTIONS

Fill the hopper with ice and replace the lid. Allow 10 to 15 minutes for the cold plate to cool down. Repeat this

procedure whenever the dispenser has been standing overnight or other long periods without ice use. Start up

the beverage system and adjust faucets to the proper brix. Contact your local syrup distributor for complete

information on the beverage system.

To dispense ice, hold cup under ice chute and press the appropriate size button on the ice portion control lo-

cated above the ice chute. An extra ice portion may be obtained by pressing the increase key (

Y

) before press-

ing the button.

For beverage dispensing, place a cup on the cup rest against the faucet lever of the desired flavor. Beverage

will be dispensed automatically filling the cup and shutting off. A delay feature is provided in the faucet controller

to “top-off”the drink after shut off.

CAUTION: Use caution to avoid spilling ice when filling dispenser. Clean up immediately

any spilled ice from filling or operating the unit. To prevent contamination of ice, the lid

must be installed at the unit at all times.

ICE PORTIONING SYSTEM OPERATION

INDICATOR LIGHT

DECREASE

SMALL

LARGE

MEDIUM

X-LARGE

INCREASE

FIGURE 7. CUP SIZE LABEL

The ice portioning system consists of three main components:

1. Ice Portion Control

2. Ice Gate Mechanism

3. Solenoid Operated Air Valve

When a size button on the ice portion control is pressed, the control supplies a voltage to the air valve for a brief

period of time. The air cylinder attached to the ice gate will then open the ice gate for a short time allowing ice to

be dispensed from the ice chute.

The ice portion control has five modes to allow adjustment of the ice portions and for normal operation. They

are as follows: (Refer to Figure 7)

MODE

INDICATOR STATUS

Normal operation

Green

Cleaning mode

Red/Amber flashing

Normal ice portion adjustment

Amber

Extra ice portion adjustment

Red

Agitation refill time adjustment

Amber flashing

The control will return to Normal Operation Mode (green indicator) automatically if a button has not been oper-

ated for a period of one minute whenever one of the three adjustment modes have been accessed.

Содержание remcor DB275--BCP

Страница 1: ...r s Manual PRINTED IN U S A IMI CORNELIUS INC 1997 Part No 620906904 December 1997 Revision D Revised February 1998 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood...

Страница 2: ...NSING OPERATION 7 EXTRA ICE PORTION ADJUSTMENT 8 CLEANING INSTRUCTIONS 8 DISPENSER 8 COLD PLATE 8 BEVERAGE SYSTEM CLEANING AND SANITIZING 9 MAINTENANCE 10 DAILY OR AS REQUIRED 10 WEEKLY OR AS REQUIRED...

Страница 3: ...CHEMATIC 5 FIGURE 6 PLUMBING SCHEMATIC 5 FIGURE 7 CUP SIZE LABEL 6 FIGURE 8 WIRING DIAGRAM 11 FIGURE 9 ICE SOFT DRINK POST MIX DISPENSER EXPLODED VIEW AND PART LIST 14 FIGURE 10 CABINET ICE BIN ASSEMB...

Страница 4: ...4 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 52189 52189 52189 52189 52189...

Страница 5: ...large chunks can void warranty The dispenser agitation is not designed to be an ice crusher Use of large chunks of ice which jam up inside the hopper will cause failure of the agitator motor and damag...

Страница 6: ...ities out the bot tom of the unit refer to the mounting template Figure 4 for locating the required clearance holes in the counter 3 DRAIN CONNECTION Use the insulated tubing and clamp provided with t...

Страница 7: ...31 30 23 41 1 2 4 1 2 1 11 16 8 14 6 1 3 16 REMOVABLE PANEL FOR REAR HOOKUP OF BEVERAGE TUBING AND AIR CO2 LINES ELECTRICAL POWER CORD REMOVABLE HOLE PLUGS 2 FOR REAR HOOKUP OF DRIP TRAY DRAIN MANUAL...

Страница 8: ...ARB WATER FAUCETS VIEWED FROM THIS SIDE 2 ICE SOFT DRINK POST MIX DISPENSER ITEMS OUTSIDE BROKEN LINES ARE NOT INCLUDED 15 50 PSIG OPTIONAL FOR DIET OR ROOT BEER REGULATORS 5 15 PSIG FIGURE 5 BEVERAGE...

Страница 9: ...any spilled ice from filling or operating the unit To prevent contamination of ice the lid must be installed at the unit at all times ICE PORTIONING SYSTEM OPERATION INDICATOR LIGHT DECREASE SMALL LAR...

Страница 10: ...witch wiring to the ice portion control or if an ice gate binding condition occurred during the sample The indicator light will display solid red briefly after a sample is dispensed if the ice gate cy...

Страница 11: ...t will alternately display red amber B To empty the ice from the ice chute press any of the size buttons The ice gate will then open to allow the ice chute to empty The ice gate will automatically clo...

Страница 12: ...ep 2 to the cleaning tank Hook up a gas disconnect fitting to the tank and pressurize with 60 to 80 psig CO2 Energize the beverage faucet continuously for 1 minute to remove all air bubbles Continue t...

Страница 13: ...tervals indicated below DAILY or as required Remove foreign material from vending area sink to prevent drain blockage WEEKLY or as required Clean vending area Check for proper water drainage from the...

Страница 14: ...HT 2 4 V W H T WHT B L K B L K RED PNEUMATIC GATE SOLENOID 9 BLK B L U E B L K PRP YEL 1 4 2 3 L N CYLINDER MAGNETIC SWITCH BLK BLK BLK BLK GROUND YEL ELECTRIC SHOCK HAZARD DISCONNECT POWER BEFORE SER...

Страница 15: ...E WATER IN HOPPER A Blocked drain A Open up flush out drain SLUSHY ICE WATER IN HOPPER B Unit not level B Level unit C Poor ice quality due to water quality or ice maker problems C Install water filte...

Страница 16: ...otor capacitor I Replace capacitor J Ice gate not aligned to ice chute J Check alignment of ice gate to slot in ice chute K Agitate relay wiring incorrect K Red wire should be connected to terminal of...

Страница 17: ...9 70055 Nut Clip 2 10 620025701 Splash Panel 1 11 52216 Drip Tray 1 12 10145 Mounting Pin Drip Tray 2 13 51455 Rear Panel 1 14 70075 Nut 5 15 70171 Screw Phil Truss Hd No 8 32 By 3 8 In Long 8 16 2790...

Страница 18: ...2939 Motor 120 VAC 1 5 52777 Motor Insulation 1 6 28117 Motor Support 1 7 52162 Cover Cold Plate 1 8 30439 Junction Box 1 9 32682 Transformer Assembly 24 VAC 2 10 28081 Cover Electric Box 1 11 70215 S...

Страница 19: ...ype A 4 10 32953 Switch Ice Chute Interlock 1 11 70828 Air Valve Solenoid Assembly 1 12 620025615 Bracket Air Valve Regulator Mounting 1 13 70017 Nut 10 32 Locking 3 14 51856 Gasket Conduit 1 15 70016...

Страница 20: ...1 3 32714 Diode Assembly 1 4 31107 Terminal Board 1 5 32503 Relay Solid State 1 30995 Power Cord 1 32956 Cable Ice Chute Interlock 1 620305405 Harness Ice Portion Control 1 6 32958 Rectifier 1 7 3224...

Страница 21: ...itator Motor Heater 3 28377 Bracket Back Motor Plate 4 28378 Bracket Motor Plate 5 70250 1 4 20 x 1 2 Truss Hd Phl MS Screw 6 70048 1 4 Int tooth Lw Plated 7 70341 Spring 8 52777 Insulation Motor 9 28...

Страница 22: ...ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D...

Страница 23: ...CORPORATE HEADQUARTERS Remcor Incorporated 500 Regency Drive Glendale Heights IL 60139 630 539 6850...

Отзывы: