NORMAL OPERATION

To dispense ice, hold a cup directly under the ice chute, then press the appropriate size button on the ice por-

tion control. To obtain a full cup of ice, press the increase button followed by the appropriate size button. The ice

portion control will not dispense ice and will display a flashing green indicator light if sufficient ice is not avail-

able in the ice chute to dispense the selected size. The indicator light will return to solid green and ice dispens-

ing will resume after the ice chute has been filled.

The amount of ice dispensed for each size is changed in the Normal and Extra Ice Adjustment Modes. To ac-

cess the adjustment modes, press the decrease and increase button at the same time. The control will advance

to the next mode in the sequence as shown in the table on page 6 and the indicator light will change to identify

which mode is currently active.

CLEAN MODE

Access this mode when cleaning the ice chute. Refer to Cleaning Instructions on pages 7 thru 9.

NORMAL ICE PORTION ADJUSTMENT

From the Normal Operation Mode (green indicator), press both the decrease and increase buttons at the same

time twice. The amber indicator verifies that the normal portion adjustment mode has ben accessed.

To change the amount of ice dispensed, press and hold down the size button for the desired size to be

changed. While holding the size button, press the decrease or increase button to decrease/increase the ice por-

tion size. When the minimum ice portion adjustment has been reached, the indicator will flash at a slow rate; at

the maximum adjustment, the indicator will flash at a fast rate. After releasing the size button, the indicator light

will flash green for five seconds. During this time period a sample can be obtained to check the portion size by

pressing the size key. The indicator light will return to amber (normal portion adjustment mode) after the sample

is dispensed.

The indicator light will flash red after dispensing a sample, if an open circuit exists in the ice gate cylinder switch

wiring to the ice portion control or if an ice gate binding condition occurred during the sample. The indicator light

will display solid red briefly after a sample is dispensed if the ice gate cylinder switch was shorted.

To return to normal operation press the decrease and increase buttons at the same time, press twice.

AGITATION REFILL TIME ADJUSTMENT

To adjust the amount of ice chute refill agitation. begin by accessing the Extra Ice Portion Adjustment Mode

(red Indicator). Next, press and hold for the decrease and increase buttons for three seconds until the indicator

flashes amber. The indicator will flash up to four times, one flash corresponds to the minimum amount of refill

agitation and four flashes corresponds to the maximum amount of refill agitation. Change the amount of refill

agitation by pressing one of the four size buttons -- the small button representing the minimum amount of refill

agitation. Increase the amount of refill agitation if the ice chute does not refill properly after dispensing ice.

To return to Normal Operation Mode, press the decrease and increase buttons at the same time.

MANUAL ICE DISPENSING OPERATION

A pushbutton switch is provided on the upper front panel (see Figure 1) to manualy dispense ice. This system

can be used in the event of a malfunction with the ice portion control or for dispensing ice in portions other than

cup-size. Depress and hold the pushbutton until the desired amount of ice is dispensed.

If a problem with the Air/CO

2

ice gate system should occur, a manual air valve is located on the right side of the

upper front panel. The function of this valve is to remove Air/CO

2

pressure on the ice gate should a gate

malfunction occur. Move the valve toggle switch to the “manual”position (to the right) and push the gate back to

its open position. Ice can now be dispensed by depressing the manual ice dispense. switch. When the problem

with the Air/CO

2

system has been corrected, move the toggle switch left to the “auto”position to restore the unit

to the ice portioning mode of operation.

CAUTION: The gate closes immediately when the toggle switch is moved to the auto

position. Do not place fingers or foreign objects into the ice chute when operating the

toggle switch.

Содержание remcor DB275--BCP

Страница 1: ...r s Manual PRINTED IN U S A IMI CORNELIUS INC 1997 Part No 620906904 December 1997 Revision D Revised February 1998 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood...

Страница 2: ...NSING OPERATION 7 EXTRA ICE PORTION ADJUSTMENT 8 CLEANING INSTRUCTIONS 8 DISPENSER 8 COLD PLATE 8 BEVERAGE SYSTEM CLEANING AND SANITIZING 9 MAINTENANCE 10 DAILY OR AS REQUIRED 10 WEEKLY OR AS REQUIRED...

Страница 3: ...CHEMATIC 5 FIGURE 6 PLUMBING SCHEMATIC 5 FIGURE 7 CUP SIZE LABEL 6 FIGURE 8 WIRING DIAGRAM 11 FIGURE 9 ICE SOFT DRINK POST MIX DISPENSER EXPLODED VIEW AND PART LIST 14 FIGURE 10 CABINET ICE BIN ASSEMB...

Страница 4: ...4 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 52189 52189 52189 52189 52189...

Страница 5: ...large chunks can void warranty The dispenser agitation is not designed to be an ice crusher Use of large chunks of ice which jam up inside the hopper will cause failure of the agitator motor and damag...

Страница 6: ...ities out the bot tom of the unit refer to the mounting template Figure 4 for locating the required clearance holes in the counter 3 DRAIN CONNECTION Use the insulated tubing and clamp provided with t...

Страница 7: ...31 30 23 41 1 2 4 1 2 1 11 16 8 14 6 1 3 16 REMOVABLE PANEL FOR REAR HOOKUP OF BEVERAGE TUBING AND AIR CO2 LINES ELECTRICAL POWER CORD REMOVABLE HOLE PLUGS 2 FOR REAR HOOKUP OF DRIP TRAY DRAIN MANUAL...

Страница 8: ...ARB WATER FAUCETS VIEWED FROM THIS SIDE 2 ICE SOFT DRINK POST MIX DISPENSER ITEMS OUTSIDE BROKEN LINES ARE NOT INCLUDED 15 50 PSIG OPTIONAL FOR DIET OR ROOT BEER REGULATORS 5 15 PSIG FIGURE 5 BEVERAGE...

Страница 9: ...any spilled ice from filling or operating the unit To prevent contamination of ice the lid must be installed at the unit at all times ICE PORTIONING SYSTEM OPERATION INDICATOR LIGHT DECREASE SMALL LAR...

Страница 10: ...witch wiring to the ice portion control or if an ice gate binding condition occurred during the sample The indicator light will display solid red briefly after a sample is dispensed if the ice gate cy...

Страница 11: ...t will alternately display red amber B To empty the ice from the ice chute press any of the size buttons The ice gate will then open to allow the ice chute to empty The ice gate will automatically clo...

Страница 12: ...ep 2 to the cleaning tank Hook up a gas disconnect fitting to the tank and pressurize with 60 to 80 psig CO2 Energize the beverage faucet continuously for 1 minute to remove all air bubbles Continue t...

Страница 13: ...tervals indicated below DAILY or as required Remove foreign material from vending area sink to prevent drain blockage WEEKLY or as required Clean vending area Check for proper water drainage from the...

Страница 14: ...HT 2 4 V W H T WHT B L K B L K RED PNEUMATIC GATE SOLENOID 9 BLK B L U E B L K PRP YEL 1 4 2 3 L N CYLINDER MAGNETIC SWITCH BLK BLK BLK BLK GROUND YEL ELECTRIC SHOCK HAZARD DISCONNECT POWER BEFORE SER...

Страница 15: ...E WATER IN HOPPER A Blocked drain A Open up flush out drain SLUSHY ICE WATER IN HOPPER B Unit not level B Level unit C Poor ice quality due to water quality or ice maker problems C Install water filte...

Страница 16: ...otor capacitor I Replace capacitor J Ice gate not aligned to ice chute J Check alignment of ice gate to slot in ice chute K Agitate relay wiring incorrect K Red wire should be connected to terminal of...

Страница 17: ...9 70055 Nut Clip 2 10 620025701 Splash Panel 1 11 52216 Drip Tray 1 12 10145 Mounting Pin Drip Tray 2 13 51455 Rear Panel 1 14 70075 Nut 5 15 70171 Screw Phil Truss Hd No 8 32 By 3 8 In Long 8 16 2790...

Страница 18: ...2939 Motor 120 VAC 1 5 52777 Motor Insulation 1 6 28117 Motor Support 1 7 52162 Cover Cold Plate 1 8 30439 Junction Box 1 9 32682 Transformer Assembly 24 VAC 2 10 28081 Cover Electric Box 1 11 70215 S...

Страница 19: ...ype A 4 10 32953 Switch Ice Chute Interlock 1 11 70828 Air Valve Solenoid Assembly 1 12 620025615 Bracket Air Valve Regulator Mounting 1 13 70017 Nut 10 32 Locking 3 14 51856 Gasket Conduit 1 15 70016...

Страница 20: ...1 3 32714 Diode Assembly 1 4 31107 Terminal Board 1 5 32503 Relay Solid State 1 30995 Power Cord 1 32956 Cable Ice Chute Interlock 1 620305405 Harness Ice Portion Control 1 6 32958 Rectifier 1 7 3224...

Страница 21: ...itator Motor Heater 3 28377 Bracket Back Motor Plate 4 28378 Bracket Motor Plate 5 70250 1 4 20 x 1 2 Truss Hd Phl MS Screw 6 70048 1 4 Int tooth Lw Plated 7 70341 Spring 8 52777 Insulation Motor 9 28...

Страница 22: ...ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D...

Страница 23: ...CORPORATE HEADQUARTERS Remcor Incorporated 500 Regency Drive Glendale Heights IL 60139 630 539 6850...

Отзывы: