background image

8

620906904

EXTRA ICE PORTION ADJUSTMENT

The adjustment of Extra Ice Portion is accomplished in the same manner as ice portions, except the indicator

light displays red. To access this mode press both the decrease and increase buttons simultaneously three

times for the Normal Operation Mode (green indicator). The indicator will display red.

CLEANING INSTRUCTIONS

DISCONNECT POWER BEFORE CLEANING: Do not use metal scrapers, sharp objects or abrasives on the

ice storage hopper and top cover as damage may result. Do not use solvents or other cleaning agents, as they

may attack the plastic material.

Dispenser

1. Clean the ice storage hopper at lease once a month.

2. Remove, (unscrew) agitator retainer and lift off the agitator. Wash and rinse them thoroughly.

3. Wash down the inside of the hopper and top cover with a mild detergent solution and rinse thoroughly to

remove all traces of detergent.

4. Replace the agitator and agitator retainer.

5. Sanitize the inside of the hopper and agitator with a solution of 1/2 ounce of household bleach in 1 gallon of

water. (200PPM)

6. Clean and sanitize the ice chute as described below:

A. Enter the Clean Mode of the ice portion control by pressing the decrease and increase button at the

same time. The indicator light will alternately display red/amber.

B. To empty the ice from the ice chute, press any of the size buttons. The ice gate will then open to allow

the ice chute to empty. The ice gate will automatically close after the ice chute has been emptied.

C. Remove the 4 thumbscrews attaching the upper service panel and remove the panel.

D. Remove the 2 thumbscrews attaching the ice chute strap and remove the strap.

E. Remove the 4 thumbscrews that secure the ice tube to the ice hopper. Remove the ice chute and gate

cover. Power to the ice portion control and beverage valves will be interrupted while the ice chute is

removed.

F.

Wash ice chute, gate slide and gate cover in detergent soap solution. Then rinse thoroughly with plain

water. Sanitize as described in step 5.

G. Replace components removed for cleaning in reverse order of removal.

H. Portion control will automatically return to Normal operating mode (green indicator) after the ice chute

is replaced.

COLD PLATE

1. Carefully remove screws holding beverage faucet panel and bring forward.

2. Slide the cold plate cover back. (Remove shipping tape and discard).

3. Remove any debris from the drain trough and spring. Check that drain holes are not clogged.

4. Wash down the inside of the cold plate, tray, and cover with a mild detergent solution and rinse. A small,

long-handled brush will be found helpful in reaching the corners.

5. Slide the cover forward, taking care that it is securely positioned on the cold plate.

Содержание remcor DB275--BCP

Страница 1: ...r s Manual PRINTED IN U S A IMI CORNELIUS INC 1997 Part No 620906904 December 1997 Revision D Revised February 1998 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood...

Страница 2: ...NSING OPERATION 7 EXTRA ICE PORTION ADJUSTMENT 8 CLEANING INSTRUCTIONS 8 DISPENSER 8 COLD PLATE 8 BEVERAGE SYSTEM CLEANING AND SANITIZING 9 MAINTENANCE 10 DAILY OR AS REQUIRED 10 WEEKLY OR AS REQUIRED...

Страница 3: ...CHEMATIC 5 FIGURE 6 PLUMBING SCHEMATIC 5 FIGURE 7 CUP SIZE LABEL 6 FIGURE 8 WIRING DIAGRAM 11 FIGURE 9 ICE SOFT DRINK POST MIX DISPENSER EXPLODED VIEW AND PART LIST 14 FIGURE 10 CABINET ICE BIN ASSEMB...

Страница 4: ...4 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 70924 52189 52189 52189 52189 52189...

Страница 5: ...large chunks can void warranty The dispenser agitation is not designed to be an ice crusher Use of large chunks of ice which jam up inside the hopper will cause failure of the agitator motor and damag...

Страница 6: ...ities out the bot tom of the unit refer to the mounting template Figure 4 for locating the required clearance holes in the counter 3 DRAIN CONNECTION Use the insulated tubing and clamp provided with t...

Страница 7: ...31 30 23 41 1 2 4 1 2 1 11 16 8 14 6 1 3 16 REMOVABLE PANEL FOR REAR HOOKUP OF BEVERAGE TUBING AND AIR CO2 LINES ELECTRICAL POWER CORD REMOVABLE HOLE PLUGS 2 FOR REAR HOOKUP OF DRIP TRAY DRAIN MANUAL...

Страница 8: ...ARB WATER FAUCETS VIEWED FROM THIS SIDE 2 ICE SOFT DRINK POST MIX DISPENSER ITEMS OUTSIDE BROKEN LINES ARE NOT INCLUDED 15 50 PSIG OPTIONAL FOR DIET OR ROOT BEER REGULATORS 5 15 PSIG FIGURE 5 BEVERAGE...

Страница 9: ...any spilled ice from filling or operating the unit To prevent contamination of ice the lid must be installed at the unit at all times ICE PORTIONING SYSTEM OPERATION INDICATOR LIGHT DECREASE SMALL LAR...

Страница 10: ...witch wiring to the ice portion control or if an ice gate binding condition occurred during the sample The indicator light will display solid red briefly after a sample is dispensed if the ice gate cy...

Страница 11: ...t will alternately display red amber B To empty the ice from the ice chute press any of the size buttons The ice gate will then open to allow the ice chute to empty The ice gate will automatically clo...

Страница 12: ...ep 2 to the cleaning tank Hook up a gas disconnect fitting to the tank and pressurize with 60 to 80 psig CO2 Energize the beverage faucet continuously for 1 minute to remove all air bubbles Continue t...

Страница 13: ...tervals indicated below DAILY or as required Remove foreign material from vending area sink to prevent drain blockage WEEKLY or as required Clean vending area Check for proper water drainage from the...

Страница 14: ...HT 2 4 V W H T WHT B L K B L K RED PNEUMATIC GATE SOLENOID 9 BLK B L U E B L K PRP YEL 1 4 2 3 L N CYLINDER MAGNETIC SWITCH BLK BLK BLK BLK GROUND YEL ELECTRIC SHOCK HAZARD DISCONNECT POWER BEFORE SER...

Страница 15: ...E WATER IN HOPPER A Blocked drain A Open up flush out drain SLUSHY ICE WATER IN HOPPER B Unit not level B Level unit C Poor ice quality due to water quality or ice maker problems C Install water filte...

Страница 16: ...otor capacitor I Replace capacitor J Ice gate not aligned to ice chute J Check alignment of ice gate to slot in ice chute K Agitate relay wiring incorrect K Red wire should be connected to terminal of...

Страница 17: ...9 70055 Nut Clip 2 10 620025701 Splash Panel 1 11 52216 Drip Tray 1 12 10145 Mounting Pin Drip Tray 2 13 51455 Rear Panel 1 14 70075 Nut 5 15 70171 Screw Phil Truss Hd No 8 32 By 3 8 In Long 8 16 2790...

Страница 18: ...2939 Motor 120 VAC 1 5 52777 Motor Insulation 1 6 28117 Motor Support 1 7 52162 Cover Cold Plate 1 8 30439 Junction Box 1 9 32682 Transformer Assembly 24 VAC 2 10 28081 Cover Electric Box 1 11 70215 S...

Страница 19: ...ype A 4 10 32953 Switch Ice Chute Interlock 1 11 70828 Air Valve Solenoid Assembly 1 12 620025615 Bracket Air Valve Regulator Mounting 1 13 70017 Nut 10 32 Locking 3 14 51856 Gasket Conduit 1 15 70016...

Страница 20: ...1 3 32714 Diode Assembly 1 4 31107 Terminal Board 1 5 32503 Relay Solid State 1 30995 Power Cord 1 32956 Cable Ice Chute Interlock 1 620305405 Harness Ice Portion Control 1 6 32958 Rectifier 1 7 3224...

Страница 21: ...itator Motor Heater 3 28377 Bracket Back Motor Plate 4 28378 Bracket Motor Plate 5 70250 1 4 20 x 1 2 Truss Hd Phl MS Screw 6 70048 1 4 Int tooth Lw Plated 7 70341 Spring 8 52777 Insulation Motor 9 28...

Страница 22: ...ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D...

Страница 23: ...CORPORATE HEADQUARTERS Remcor Incorporated 500 Regency Drive Glendale Heights IL 60139 630 539 6850...

Отзывы: