Countertop Icemaker IMD Glacier Series Installation Manual
© 2018, Cornelius Inc.
- 29 -
Publication Number: 620068501INS
TROUBLE SHOOTING INSTRUCTIONS FOR
IMD GLACIER 600-30, 115V / 60HZ
1.
Stand-by Condition: Line voltage is present between Black and White wires
2.
Timing Condition: Voltage is present between White & Yellow only when the dispense switch is activated.
3.
Run Condition: Line voltage is switched on at Red wire.
4.
Full Bin Condition: 0 VAC between Black and White wires.
This test will require a Multimeter and a small probe set. System status: Stand-by condition.
A. Connect the meter’s ground probe to the White wire.
B. With the meter adjusted to read 120/230 VAC. Measure voltage between Black and White.
C. With unit calling for ice. This measurement should be line voltage.
D. Measurement between White and Red should be 0 VAC.
E. Measure White and Yellow. Correct reading is 0 VAC.
F. Depress the dispense switch / lever. The White / Yellow measurement should change from 0 VAC line
voltage.
Figure 24 Trouble shooting