![Cornelius IMD GLACIER 500-30 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/cornelius/imd-glacier-500-30/imd-glacier-500-30_installation-manual_2668202016.webp)
Countertop Icemaker IMD Glacier Series Installation Manual
Publication Number: 620068501INS
- 12 -
© 2018, Cornelius Inc.
NOTE: Drain connection should be completed before step 3.
3.
Units placed on a counter must either use minimum of 4 inch (101.6mm) high legs (Provided in the installation
kit along with the unit) or be sealed to the counter top all around the base except Drip Tray with NSF listed seal-
ant / food grade sealant as per local codes. To avoid disturbing the seal, complete the installation prior to seal-
ing.
W
ATER
I
NLET
H
OOK
-
UP
1.
Water Inlet
- Fitting is a 1/4” (6.35mm) SAE male flare located at the rear of the unit. Connect water supply
with a 1/4” (6.35mm) or larger copper or flexible tubing.
CAUTION:
!
Unit must be installed with only potable water.
NOTE: A shut-off valve with a loop of additional tubing for service is recommended.
2.
Water Pressure
- Unless otherwise specified, the unit is designed to operate on water pressures between 10
P.S.I. (0.69 Mpa) and 90 P.S.I. (0.62 Mpa)A recommended water supply is with temperatures between
50° F - 90° F (10° C - 32° C) with a pressure between 20-70 p.s.i (0.138 - 0.48 Mpa).
NOTE: For pressures above 90 P.S.I. (0.62 Mpa) a regulator must be installed.
NOTE: This equipment must be installed with adequate backflow protection to comply with applicable
federal state and local codes.
3.
Filter
- IMF (Phosphate Feeder) Water Filters and Scale inhibitors are
not
recommended for use with the Con-
tinuous Flow Ice-Maker, Taste & Odour only should be used. Total dissolved solids in the water should be within
the below specified limit
MIN dissolved solids = 270 PPM(TDS).
Max dissolved solids = 500 PPM(TDS).
NOTE: Water inlet for the Ice Maker should not be with RO Filtration System.
NOTE: Unit must be installed per local plumbing code.
E
LECTRICAL
S
UPPLY
1.
Power Access
- Connect the unit with power cord provided. An adapter plug for the particular country needs to
be provided by the installer.
2.
Fused Line
- Should be a dedicated circuit checked and sized according to electrical rating shown on unit
nameplate.
3.
This unit should not be connected to a GFI / GFCI receptacle.
NOTE: Unit must be installed per local electrical code.
NOTE: This equipment is intended for use only in premises with a service current capacity > 100A per
phase. User and/or installer must determine the service capacity is sufficient, on consultation
with the supply authority is necessary.
Содержание IMD GLACIER 500-30
Страница 39: ......
Страница 40: ...Cornelius Inc www cornelius com...