![Cornelius IMD GLACIER 500-30 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/cornelius/imd-glacier-500-30/imd-glacier-500-30_installation-manual_2668202019.webp)
COUNTER
ELBOW
TUBING
T-FITTING
1”( 25.4MM)
TUBING
1/2” - 1”(12.7-25.4MM)
ELBOW
1”( 25.4MM)
Figure 12. Drain connection (Type 1)
COUNTER
ELBOW
T-FITTING
1”( 25.4MM)
TUBING
Figure 12A. Drain connection (Type 2)
Countertop Icemaker IMD Glacier Series Installation Manual
© 2018, Cornelius Inc.
- 15 -
Publication Number: 620068501INS
I
NITIAL
S
TART
U
P
, C
HECKS
& A
DJUSTMENT
I
NSTRUCTIONS
NOTE: Do not start unit before completing above Installation Instructions.
Turn on water supply and main power switch (located on top of electric box). All IMD Glacier series units are
equipped with a 45 second delay timer. This means that the refrigeration system will not start until 45 seconds of
dispense are accumulated in the timer. Start the refrigeration system by depressing the ice dispense lever for 45
seconds. Make the following system checks:
NOTE: If unit will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down unit. If water level drops below bottom of reservoir, unit must
shut down. Adjustment is made by moving magnet up or down.
Water Level
- If necessary, adjust float by bending float arm up or down as needed. Push float assembly down until
unit stops running. Release float and unit will restart. Keep water in reservoir at level line while unit is in operation.