Countertop Icemaker IMD Glacier Series Installation Manual
© 2018, Cornelius Inc.
- 11 -
Publication Number: 620068501INS
P
REPARATION
OF
I
NSTALLATION
S
ITE
The refrigeration system on air cooled units requires airflow, so a well-ventilated area should be chosen. Ice Maker
should not be placed in direct sunlight or in close proximity of any object placing additional heat load on
refrigeration system.
TOP LOUVERS ARE ONLY FOR IMD GLACIER 600-30
AIR OUT
AIR IN
AIR IN
AIR OUT
Figure 10. Air Flow
1.
Minimum clearance must be maintained, free of any obstruction, for air flow. Refer the below table for the clear-
ances required for the specific model.
Model
Minimum Clearance required free of obstructions, in Inches (mm).
Climate class
Top
Sides
Back
IMD Glacier 500-30
0
6 (152.4)
6 (152.4)
T
IMD Glacier 600-30
12 (304.8)
6 (152.4)
6 (152.4)
!
WARNING:
Keep ventilation openings in the appliance enclosure or in the built-in structure, clear of obstruction.
2.
With template provided make the necessary provisions in the counter (as shown in Figure 11 on page 14) for
drain. Provisions for water inlet & Electrical connections are available at rear side of the unit.