background image

A. Power cord for the carbonator 

pump motor is not connected.

A. Carbonator pump is powered off 

the main control board inside the 
electrical box of the unit. Check 
that the umbilical cord is con-
nected from the unit to the pump 
motor terminal box.

A. Carbonator pump motor is dis-

abled.

B. Probes were dry, unit was pow-

ered up, water was not turned on, 
and carbonator did not fill. 

C. Water service was interrupted for 

more than 5 minutes.

A. Check the enable/disable switch 

on the carbonator pump terminal 
box and enable it, if necessary.

B. This results in a 5 minute timeout. 

Unplugging the unit and plugging 
it in will reset the unit and start the 
carbonator pump.

C. Unplugging the unit and plugging 

it in will reset the unit and start the 
carbonator pump.

A. Lower liquid level probe reads 

“dry” while upper probe reads 
“wet”

A. Check color of leads going to 

probes. Black should go to bottom 
probe and white to top probe. 
Reverse if incorrect.

A. Poor electrical connections 

between carbonator tank and 
main control board.

B. Broken wires between carbonator 

tank and main control board.

C. Defective liquid level probes.

A. Check connections at carbonator 

tank and at connector J4 on the 
main control board.

B. Replace wire harness.

C. Replace both liquid level probes

FlavorFusion Installation Manual                             

Publication Number: 620055764INS

- 18 -

© 2012, IMI Cornelius Inc.

Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of 
beverage system

.

Carbonator Troubleshooting

Symptom

Cause

Remedy

Carbonator pump 
does not start to fill 
tank

Power cord is con-
nected but carbonator 
pump does not run.

Carbonator pump is 
short cycling with 
every drink drawn

Carbonator tank over-
fills, overflows 
through relief valve, 
and pump shuts off 
after 5 minutes.

Содержание FlavorFusion

Страница 1: ...TH COLD CARBONATION Installation Manual Release Date February 20 2012 Publication Number 620055764INS Revision Date N A Revision A Visit the IMI Cornelius web site at www cornelius com for all your Li...

Страница 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Страница 3: ...djust Carbonator CO2 Regulator and Turn Water Inlet Supply Line ON 5 Unit Operation 5 Gate Restrictor Plate and Adjustment 6 Programming Mode 7 Programming Mode Flashing Sequences 7 Setting Water Flow...

Страница 4: ......

Страница 5: ...te injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnhowtooper...

Страница 6: ...use residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention MUST be...

Страница 7: ...s not designed to be an ice crusher Use of large chunks of ice which jam up inside the hopper will cause failure of the agitator motor and damage to the hopper If bagged ice is used it must be careful...

Страница 8: ...gure 7Figure 7 Route the drain tube to an open drain with the end of the tube above the flood level of the drain Use the tubing fittings clamps and insulation provided with the Dispenser to assemble t...

Страница 9: ...age around the valve shaft 2 The carbonator CO2 regulator is fixed at a nominal 75 psi 3 Open one of the post mix dispensing valves to exhaust trapped air inside the carbonator tank CAUTION Never oper...

Страница 10: ...th small openings To adjust the gate restrictor plate loosen the 4 nuts that hold the ice chute assembly to the bin The restrictor plate can now be moved up or down When the restrictor plate is fully...

Страница 11: ...dispense button LED flashes in a sequence cycle according to one 1 of six 6 dispense types For Brand Keypads only dispense types 1 and 2 are used For Bonus Flavor Keypads dispense types 3 through 6 a...

Страница 12: ...the appropriate nozzle and press the left program button for a 4 second dispense of carbonated water There should be approximately 10 oz dispensed 4 If necessary adjust the water flow control empty r...

Страница 13: ...sing and holding both programming buttons for 4 sec onds Setting a Button to Dispense Non carbonated Water Only 1 Program the designated button to dispense non carbonated water see Programming Mode 2...

Страница 14: ...UNTING TEMPLATE 30 26 3 8 1 13 16 1 5 16 18 5 8 12 9 3 1 2 9 1 2 11 23 21 1 4 30 31 1 2 REMOVABLE SINK RECOMMENDED COUNTER OPENING SIZE 9 X 12 FOR UTILITIES AND BEVERAGE TUBING OPENING CAN BE LOCATED...

Страница 15: ...orFusionInstallationManual 2012 IMI Cornelius Inc 11 Publication Number 620055764INS DRIP TRAY DRAIN ASSEMBLY DRAIN LINE 1 I D PLASTIC TUBING 6 WITH INSULATION HOSE CLAMP Figure 7 Drip Tray Drain Asse...

Страница 16: ...FlavorFusion Installation Manual Publication Number 620055764INS 12 2012 IMI Cornelius Inc FLOW DIAGRAM Figure 8 Flow Diagram...

Страница 17: ...FlavorFusionInstallationManual 2012 IMI Cornelius Inc 13 Publication Number 620055764INS WIRING DIAGRAM ELECTRIC SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING UNIT Figure 9 Wiring Diagram 120V Unit...

Страница 18: ...FlavorFusion Installation Manual Publication Number 620055764INS 14 2012 IMI Cornelius Inc WIRING SCHEMATIC Figure 10 Wiring Schematic...

Страница 19: ...itch D Electrical board driver circuit is defective E Gear motor has open circuit F Reed switch is not activated Improper assembly of upper ice chute to lower chute G Broken wire in the 2 wire harness...

Страница 20: ...emptied while power was applied to unit 5 min ute time out of carbonator pump motor occurred and carbonator pump is locked off B Note that this can occur while the water filter system is serviced or w...

Страница 21: ...tank blad der A Syrup supply is empty B BIB pump not working C No CO2 or compressed air supply to BIB pump or not enough pres sure A Replace BIB B Replace BIB pump C Check CO2 pressure regulator setti...

Страница 22: ...ry while upper probe reads wet A Check color of leads going to probes Black should go to bottom probe and white to top probe Reverse if incorrect A Poor electrical connections between carbonator tank...

Страница 23: ...and LOW probe reads dry THIS IS AN ERROR CONDITION Check electrical connec tions at the carbonator tank and at connector J4 on the main control board Black wire should be connected to the LOW probe a...

Страница 24: ...FlavorFusion Installation Manual Publication Number 620055764INS 20 2012 IMI Cornelius Inc...

Страница 25: ......

Страница 26: ...IMI Cornelius Inc www cornelius com...

Отзывы: