A. Power cord for the carbonator
pump motor is not connected.
A. Carbonator pump is powered off
the main control board inside the
electrical box of the unit. Check
that the umbilical cord is con-
nected from the unit to the pump
motor terminal box.
A. Carbonator pump motor is dis-
abled.
B. Probes were dry, unit was pow-
ered up, water was not turned on,
and carbonator did not fill.
C. Water service was interrupted for
more than 5 minutes.
A. Check the enable/disable switch
on the carbonator pump terminal
box and enable it, if necessary.
B. This results in a 5 minute timeout.
Unplugging the unit and plugging
it in will reset the unit and start the
carbonator pump.
C. Unplugging the unit and plugging
it in will reset the unit and start the
carbonator pump.
A. Lower liquid level probe reads
“dry” while upper probe reads
“wet”
A. Check color of leads going to
probes. Black should go to bottom
probe and white to top probe.
Reverse if incorrect.
A. Poor electrical connections
between carbonator tank and
main control board.
B. Broken wires between carbonator
tank and main control board.
C. Defective liquid level probes.
A. Check connections at carbonator
tank and at connector J4 on the
main control board.
B. Replace wire harness.
C. Replace both liquid level probes
FlavorFusion Installation Manual
Publication Number: 620055764INS
- 18 -
© 2012, IMI Cornelius Inc.
Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of
beverage system
.
Carbonator Troubleshooting
Symptom
Cause
Remedy
Carbonator pump
does not start to fill
tank
Power cord is con-
nected but carbonator
pump does not run.
Carbonator pump is
short cycling with
every drink drawn
Carbonator tank over-
fills, overflows
through relief valve,
and pump shuts off
after 5 minutes.