FlavorFusion Installation Manual
Publication Number: 620055764INS
- 6 -
© 2012, IMI Cornelius Inc.
G
ATE
R
ESTRICTOR
P
LATE
AND
A
DJUSTMENT
The rate at which ice is dispensed can be adjusted by varying the opening of the gate restrictor plate as illustrated
in Figure 1. Reducing the dispense rate of ice is especially desirable when using glasses or other containers with
small openings. To adjust the gate restrictor plate, loosen the (4) nuts that hold the ice chute assembly to the bin.
The restrictor plate can now be moved up or down. When the restrictor plate is fully up, the ice gate opening is 2-1/
2” in height, and the maximum rate of ice dispense is available (approximately 3 oz/sec). Retighten the (4) nuts to
set the desired restrictor plate opening. DO NOT EXCEED 40 IN-LB of torque.
Figure 1. Gate Restrictor Plate
NOTE: Tighten (4) nuts for fastening lower ice chute in place to 40 in-lbs (max). Draw all four nuts
tight uniformly.