A. Could be caused by excessively
long runs (over 40 ft.) of 3/8” water
supply line.
B. Low water pressure
C. Plugged water filter.
D. Water booster bladder has burst
A. Increase line size to 1/2”
B. Add water pressure booster pump
C. Change water filter
D. Replace water booster tank/blad-
der
A. Syrup supply is empty
B. BIB pump not working
C. No CO
2
or compressed air supply
to BIB pump, or not enough pres-
sure
A. Replace BIB
B. Replace BIB pump
C. Check CO
2
pressure regulator
setting. 65 psig recommended.
Replace CO
2
tank or fix compres-
sor
FlavorFusion Installation Manual
© 2012, IMI Cornelius Inc.
- 17 -
Publication Number: 620055764INS
Continued Dispenser Troubleshooting
Symptom
Cause
Remedy
Low water pressure
No Syrup or Watered
down drink dispensed