![Cornelius FCB Pinnacle 2 Flavor Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/cornelius/fcb-pinnacle-2-flavor/fcb-pinnacle-2-flavor_installation-manual_2668289019.webp)
FCB Pinnacle 2 and 4 Flavor Installation Manual
© 2003-2014, Cornelius Inc.
- 17 -
Publication Number: 560007295INS
3.
Turn three-way product valve to BRIX position. Hold a 12 ounce cup under the appropriate sample tube.
Figure 25.
4.
Press GO and wait 3-5 seconds. The unit will dispense product for 3 seconds. Discard this first sample.
5.
Hold cup under the tube again and press GO.
6.
Put sample on refractometer and read BRIX.
NOTE: Temperature compensated hand–type refractometers (P/N 511004000) are available from
Cornelius.
7.
Adjust syrup regulator to get a BRIX reading of 13 ± 1. To increase reading, turn syrup regulator clockwise.
Figure 26.
8.
After BRIX is adjusted, turn 3-way product valve to blendonator position.
9.
Repeat procedure for additional freeze cylinders.
10. Turn the freeze cylinder shutoff valves to the ON position. Press MENU, press UP until blendonator is
selected, press GO, select the desired cylinder, press ON.
Sample
Tube
Syrup
Regulator
Valve