![Cornelius FCB Pinnacle 2 Flavor Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/cornelius/fcb-pinnacle-2-flavor/fcb-pinnacle-2-flavor_installation-manual_2668289018.webp)
FCB Pinnacle 2 and 4 Flavor Installation Manual
Publication Number: 560007295INS
- 16 -
© 2003-2014, Cornelius Inc.
APPENDIX B - HISTORIC BRIX PROCEDURES
NOTE: See page 9, step 4 to determine if Appendix B Section 1 or 2 applies to the unit.
S
ECTION
1: 3-W
AY
V
ALVE
B
RIXING
P
ROCEDURE
WATER
PRESSURE SWITCH AND
WATER REGULATOR
FLOW REGULATOR
AND SOLENOID VALVE
SINGLE
CHECK
VALVE
PRODUCT PUMP
(SYRUP AND WATER
ARE MIXED)
DOUBLE
CHECK
VALVE
COOLING COIL
FREEZE
CYLINDER
BLENDONATOR
SYRUP
PRODUCT SHUTOFF
VALVE
WATER ICE BATH
3-WAY PRODUCT
BRIX VALVE
PRODUCT SAMPLE TUBE
Figure 22.
Figure 23.
Figure 24.
1.
Make sure the status of all cylinders is OFF.
2.
Press MENU, press UP until BRIX is selected, press GO, select cylinder to be BRIXed.
NOTE: Pressing CANCEL will stop the process.
Product
Shut
Off
Valve
Number
1
Cylinder
Product
Sample
Tubes
3
‐
Way
Product
Brix
Valve
Syrup
Valves