Single Target Calibration
This procedure is required only in the following cases:
-
1 or more Target replacement;
-
1 or more Clamp replacement;
-
1 or more Target and Clamp assembly replacement and no file on CD-ROM or no file received from
Service Department;
-
Calibration CD-ROM missing.
The password is “1234”.
The software will display
informations about the 2
cameras connected to the
PC.
Press OK on both message
boxes.
This warning inform you that
System and Target
calibration are already done,
but Calibration Check is still
not performed.
Press OK to continue.
Select “Target Calibration”.
Select “Calibrate 1 Target”.
Click on the SERVICE icon..
GEO 15 Service Manual - Rel. 0
2
0
6
-2016
Set the screen resolution at 1920 x 1080. Run
ServiceWindows.exe
placed on desktop.