34
Calibration Check:
This is a very important procedure that must be performed after Beam Alignment during the first
installation of the machine.
Besides the Calibration Check is used to discover if a single camera is in good state or damaged.
If the Calibration Check final result is Good, the System Calibration is not required and the Aligner is ready
for use.
Otherwise, if the Calibration Check final result is NOT Good, the System Calibration must be performed.
The password is “1234”.
The software will display information
about the 2 cameras connected to the
PC.
Press OK on both message boxes.
This warning inform you that System and
Target calibration are already done, but
Calibration Check is still not performed.
Press OK to continue.
Select "CALIBRATION CHECK”.
Click on the SERVICE icon.
GEO 15 Service Manual - Rel. 0
2
0
6
-2016
Set the screen resolution at 1920 x 1080. Run
ServiceWindows.exe
placed on desktop.