TigoMaster 2TH
– EtherNet/IP
User Manual
Copyright © 2021 CoreTigo Ltd.
Page
10
of
75
2. Safety and Requirements
2.1. General Note
This user manual is only intended for users considered to be qualified personnel. All safety messages,
property damage messages, and valid legal regulations must be observed by users.
Note:
CoreTigo Ltd. presumes that users have the technical capabilities required.
2.2. Intended Use
The TigoMaster 2TH IO-Link Wireless Master can be used to either acquire or output IO-Link field signals
to sensors, actuators, and hubs, with such signals being sent and received to a higher-level control system.
The product is intended for indoor use only and in operating temperatures of -25°C to 55°C. It is protected
by housing from damage caused by any buildup of moisture on surfaces which are in contact with the air.
It is developed for any working environment requiring protection class IP67.
Warning:
Product applications other than those described in this user manual are not permitted.
2.3. Personnel Qualification
The product may only be mounted, configured, operated, or demounted by qualified personnel. When
working with electricity, technical skills must be demonstrated under all the following circumstances:
•
Safety and health at work
•
Mounting and connecting of electrical equipment
•
Measurement and analysis of electrical functions and systems
•
Evaluation of the safety of electrical systems and equipment
Warning:
CoreTigo Ltd. does not assume any warranty or liability for damage caused to the product
due to non-compliance with security measures or incorrect installation of the product.
2.4. Power Drop for Write/Delete Access in File System
The File Allocation Table (FAT) file system in the netX firmware is subject to certain operational limitations.
Specifically, write and delete access in the file system (for the purpose of firmware update, configuration,
download, and so forth) may destroy the FAT if access cannot be completed during power drops.
Without such a proper FAT, firmware may not be found and can also not be started. Hence, it is important
to verify that the power supply of the device does not drop during write and delete access in the file system.