![CopperOptics 150-1318-02 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/copperoptics/150-1318-02/150-1318-02_manual_2666214007.webp)
Revision 01
May 30, 1997
Section 363-718-102
PG-Flex FCS-718
PairGain Engineering - Plant Series
Page 5
Table 4. Alarm Unit or PGTC Interface Unit Connector
J1-C Pin
J1-C Signal
J1-B Pin
J1-B Signal
J1-A Pin
J1-A Signal
1
LAN
1
LGND (CDS)
1
LGND (CDS)
2
N/C
2
INHIBIT
2
N/C
3
PGTC_TIP1
3
SLEEVE1
3
TESTIN1-T
4
PGTC_RING1
4
SLEEVE2
4
TESTIN1-R
5
PGTC_TIP2
5
SLEEVE3
5
TESTIN2-T
6
PGTC_RING2
6
SLEEVE4
6
TESTIN2-R
7
PGTC_TIP3
7
OH1
7
TESTIN3-T
8
PGTC_RING3
8
OH2
8
TESTIN3-R
9
PGTC_TIP4
9
OH3
9
TESTOUT1_T
10
PGTC_RING4
10
OH4
10
TESTOUT1-R
11
(BURN-IN)
11
PROCEED1
11
TESTOUT2-T
12
LOCK1
12
PROCEED2
12
TESTOUT2-R
13
LOCK2
13
PROCEED3
13
TESTOUT3-T
14
LOCK3
14
PROCEED4
14
TESTOUT3-R
15
LOCK4
15
SEIZE
15
TESTOUT4-T
16
TMAJ
16
SEZBY
16
TESTOUT4-R
17
+5_1
17
TSTALM
17
+5
18
NMA_TX
18
NMA_RX
18
NMA_DTR
19
NMA_DSR
19
N
MA_TCLK
19
NMA_RCLK
20
NMA_BUS_1
20
NMA_BUS_2
20
TESTIN4-T
21
NMA_BUS_3
21
NMA_BUS_4
21
TESTIN4-R
22
CC1TIP
22
CC1RING
22
EXT_ACO
23
CC2TIP
23
CC2RING
23
8KHZ_CC
24
SHELF_ID_NO
24
SHELF_ID_COM
24
SHELF_ID_NC
25
MAJ_AUD_NO
25
MAJ_AUD_COM
25
MAJ_AUD_NC
26
MAJ_VIS_NO
26
MAJ_VIS_COM
26
MAJ_VIS_NC
27
MIN_AUD_NO
27
MIN_AUD_COM
27
MIN_AUD_NC
28
MIN_VIS_NO
28
MIN_VIS_COM
28
MIN_VIS_NC
29
FUSEALARM
29
MAJORALARM
29
MINORALARM
30
BATT_B-
30
N/C
30
BATT_A-
31
31
31
32
PROTGND
32
GND
32
GND
Содержание 150-1318-02