Section 363-718-102
May 30, 1997
Revision 01
Page 22
PairGain Engineering - Plant Series
PG-Flex FCS-718
8. Wiring
8.1
Sections 8.2 through 8.9 describe how to connect the FCS-718. Section 8.10 verifies the installation.
All wiring to the COT shelf is performed on the backplane (Figure 2) at the back side of the shelf.
Follow the provisions of the National Electric Code (current edition) for wiring
external to the product(s).
8.2
Frame Ground and Battery.
Connect the frame ground and battery:
1
Remove the clear Plexiglas
from the backplane.
2
Remove the fuse in the equipment bay fuse panel for the circuit where the PG-Flex CO battery
wire will be terminated.
Follow local grounding practices to ensure a good frame ground connection to
PG-Flex. This frame grounding is required for secondary voltage protection of
the PG-Flex equipment.
3
Connect the frame ground (Figure 4):
a
Connect one end of the frame ground wire to the grounding lug G1 (Frame Ground).
b
Connect the other end of the frame ground wire to the CO ground termination point.
Figure 4. Connecting the Frame Ground