Encoder Management
Copley Controls Encoder Guide
50
Copley Controls
3.5: Managing Absolute Position
3.5.1: Lost Battery
Do not ignore lost battery faults and warnings if using multi-turn absolute encoders. If a battery is
removed and the system is powered off for an extended length of time, the absolute position may
need to be re-calibrated.
Some multi-turn encoders use mechanical linkage and do not require a battery to hold absolute
multi-turn information.
Single-turn encoders do not usually require a battery.
3.5.2: Mechanical Slipping
Absolute position may be lost due to mechanical slipping between the absolute encoder and the
mechanical system to the load. Always verify that there is reliable mechanical linkage with no
slipping in the mechanical system.
!
WARNING
If multi-turn absolute position is lost, damage to equipment or life may
be at risk.