To Obtain Warranty Service

Contact the Service Department at CooperSurgical to obtain a Return 

Authorization Number . This Return Authorization Number must appear on all 

correspondence regarding your warranty claim; CooperSurgical is not required 

to accept a Product returned without a Return Authorization Number .
The Product must be returned to CooperSurgical together with proof of date 

of purchase . All products must be properly disinfected prior to returning 

for service . All shipments to CooperSurgical must be insured and safely 

and securely packed, preferably in the original shipping carton . Include a 

letter explaining the problem and a reference to the Return Authorization 

Number . All return transportation and insurance charges must be prepaid 

by the customer and the customer will bear all risk of loss .
If CooperSurgical determines that the Product requires repair covered 

under this Limited Warranty, CooperSurgical will repair or replace the 

Product as provided above and will return the repaired or replacement 

Product to the customer, freight prepaid with the risk of loss passing to  

the customer upon delivery to common carrier .
If CooperSurgical determines that the Product requires a repair that is not 

covered by this Limited Warranty, CooperSurgical will either return the 

Product to the customer at the customer’s expense or contact the customer 

for further instructions . If so instructed by the customer, CooperSurgical will 

repair the Product and return the repaired Product to the customer, freight 

prepaid with risk of loss passing on the customer upon delivery to the  

common carrier . CooperSurgical shall be entitled to invoice the customer  

for the reasonable cost of non-warranty inspection and repair of the Product 

and the cost of the return freight .

NOTE:

  There are no user-serviceable parts (excluding intermittent filter 

changes) . Repairs should only be carried out by authorized CooperSurgical 

service personnel .

Содержание LEEP PRECISION LP-30-120

Страница 1: ...LEEP PRECISIONTM Smoke Evacuator 120 VAC Operating Manual REF LP 30 120 ...

Страница 2: ...r Use 2 INITIAL SETUP 2 ULPA FILTER INSTALLATION 2 OPERATING INSTRUCTIONS 2 Maintenance 3 Cleaning and Disinfection 3 Specifications 4 Reordering Information 5 Liability Statement 5 Warranty Information 6 To Obtain Warranty Service 7 EMC Compliance Information 8 Explanation of Symbols 12 i ...

Страница 3: ... removed by this device are potentially hazardous Handle according to 29 CFR 1910 1030 and OSHA 3127 1992 Occupational Exposure to Bloodborne Pathogens guidelines To prevent a fire or explosion hazard do not use the system in the presence of flammable or potentially flammable materials Do not allow fluid to be pulled into the system To prevent premature failure of the ULPA filter cylinder do not o...

Страница 4: ...able Pre Filter onto the ULPA Filter cylinder Photo B Be sure this device is firmly seated For procedures requiring close proximity plume removal i e vaginal speculum Assemble the inch Reducer Catalog number 6083 onto the port on the disposable Pre Filter top with a slight twisting motion Attach one end of an appropriate length of inch inner diameter ID Evacuation Tubing Catalog number 6084 to the...

Страница 5: ...equired during normal operation other than making sure that ample space is maintained around the unit to allow for free air flow and adequate cooling Cleaning and Disinfection After each patient use follow the combined cleaning disinfection instructions provided below for the LEEP PRECISION Smoke Evacuator CLEANING 1 Prepare an enzymatic neutral pH cleaner solution according to the Manufacturer s ...

Страница 6: ...t the wipes as necessary to ensure that all surfaces remain wet for the entire time 9 Allow the device to air dry Once dry visually inspect the device for any residual soil Repeat cleaning disinfection instructions if visible soil is present 10 Place the disinfected device in an appropriate dry storage area Specifications Use Environmental Temperature between 10 C and 40 C Relative Humidity betwee...

Страница 7: ...h and utilize natural resources prudently and rationally do not dispose of waste electrical or electronic equipment WEEE as unsorted municipal waste Contact local WEEE disposal sites Reordering Information Disposable Pre Filter Catalog REF number 52560 ULPA Filter Catalog REF number 6082 Reducer Catalog REF number 6083 Disposable Tubing inch ID Catalog REF number 6084 Liability Statement CooperSur...

Страница 8: ... by CooperSurgical nor normal wear and tear and does not apply to disposable or single or limited use items or components The sole and exclusive remedy under this Limited Warranty shall be repair or replacement as provided herein The foregoing Limited Warranty states the sole warranty made by CooperSurgical with respect to the Product and all parts thereof and is in lieu of any other warranty by C...

Страница 9: ...s repair covered under this Limited Warranty CooperSurgical will repair or replace the Product as provided above and will return the repaired or replacement Product to the customer freight prepaid with the risk of loss passing to the customer upon delivery to common carrier If CooperSurgical determines that the Product requires a repair that is not covered by this Limited Warranty CooperSurgical w...

Страница 10: ...ON Smoke Evacuator should assure that it is used in such an environment Emissions Test Compliance Electromagnetic Environment Guidance RF Emissions CISPR 11 Group 1 CooperSurgical LEEP PRECISION Smoke Evacuators use only RF energy for their internal function Therefore RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF Emissions CISPR 11 Class A...

Страница 11: ...ode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec 5 UT 95 dip in UT for 0 5 cycle ...

Страница 12: ...E1 P 80 MHz to 800 MHz 7 E1 P 800 MHz to 2 5 GHz 3 5 V1 P NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile...

Страница 13: ...imum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output rating of the transmitter in watts W according to the transmitter manufacturer For the CooperSurgical LEEP PRECISION Smoke Evacuator V1 3 Vrms E1 3 V m NOTE 1 At 80 MHz and 800 MHz the separation distan...

Страница 14: ...1 1 and CAN CSA C22 2 No 601 1 6D33 Date of Manufacture Explanation of Symbols Caution U S Federal law restricts this device to sale by or on the order of a physician RxOnly In order to preserve protect and improve the quality of the environment protect human health and utilize natural resources prudently and rationally do not dispose of waste electrical or electronic equipment WEEE as unsorted mu...

Страница 15: ...13 NOTES ...

Страница 16: ...37994 B Rev A 11 18 95 Corporate Drive Trumbull CT 06611 USA Phone 800 243 2974 Fax 800 262 0105 International Phone 1 203 601 9818 Fax 1 203 601 4747 www coopersurgical com Made in the USA ...

Отзывы: