Installation Instructions – LAS Area / Site
Instructions d’installation – LAS Area / Site
Instrucciones de instalación – LAS Area / Site

WARNING

WARNING

DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind 

that may arise from the improper, careless, or negligent installation, handling or use of this product.

 

NOTICE:

 Green ground wire provided in proper location. Do not relocate.

ATTENTION Receiving Department:

 Note actual fixture description of any shortage or noticeable damage on 

delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be 

filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Safety

: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and 

ordinances. Proper grounding is required to ensure personal safety.  

APPLICATIONS

: This lighting fixture is designed for outdoor lighting applications, and should not be used in area 

of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to 

installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation 

and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and 

maintained according to the following instructions.

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this 

product must be performed by a qualified electrician. This product must be installed in accordance 

with the applicable installation code by a person familiar with the construction and operation of the 

product and hazards involved. 

Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting 

any maintenance. Disconnect power at fuse or circuit breaker.

Risk of Fire- Refer to product label for specific minimum supply conductor requirements.

Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.

Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.

IMPORTANT: Read carefully before installing product. Retain for future reference. Failure to comply with these 

instructions may result in death, serious bodily injury and property damage.

Содержание Lumark AP

Страница 1: ...on or inside high ambient temperature enclosures It must be stored in a dry location prior to installation Do not expose lighting fixture to rain dust or other environmental conditions prior to instal...

Страница 2: ...d reinstall the door to the housing by tightening the three Allen head screws to 30 in lbs Be sure not to pinch any wires when closing the door Installation Slipfitter Mounting Arm Tools Required 2 Ph...

Страница 3: ...re 6 Pole Mount Arm Tools Required 2 Phillips screwdriver 4 5 6 mm Allen wrenches M19 Torque Wrench M19 Open End Wrench Drill optional 1 Remove the cover plate on the pole mount arm by removing the fo...

Страница 4: ...ad screws Figure 7 Torque to 10 in lbs ote N Be sure not to pinch wires between cover plate and mount arm Photocontrol Shorting Cap 1 Insert provided photocontrol or shorting cap into the receptacle a...

Страница 5: ...us que l alimentation lectrique est HORS TENSION avant de commencer l installation ou de tenter d en faire l entretien Mettez l alimentation lectrique hors tension depuis le fusible ou le disjoncteur...

Страница 6: ...hexagonale un couple de 3 4 Nm 30 po lb Assurez vous qu aucun fil n est coinc lors de la fermeture de la porte Installation Bras de montage d adaptateur embo tement Outils requis Tournevis cruciforme...

Страница 7: ...6 mm Cl dynamom trique M19 Cl fourche M19 Perceuse facultative 1 Retirez le couvre joint sur le bras de montage sur poteau en enlevant les quatre vis t te cruciforme et en utilisant la languette tiqu...

Страница 8: ...pinc entre le couvre joint et le bras de montage Interrupteur photo lectrique fiche de mise en court circuit 1 Ins rez l interrupteur photo lectrique ou fiche de mise en court circuit dans le r ceptac...

Страница 9: ...a est APAGADA antes de comenzar la instalaci n o intentar realizar cualquier tipo de mantenimiento Desconecte la alimentaci n el ctrica en el fusible o cortacircuitos Riesgo de incendio consulte la et...

Страница 10: ...apretando los tres tornillos de cabeza Allen a 30 in lb 3 39 Nm Aseg rese de no pellizcar ning n cable al cerrar la puerta Instalaci n Brazo de montaje en conector deslizante Herramientas necesarias...

Страница 11: ...ips n 2 Llaves Allen de 4 5 6 mm Llave de torsi n M19 Llave de boca M19 Taladro opcional 1 Quite la placa de la cubierta en el brazo de montaje en poste quitando los cuatro tornillos de cabeza Phillip...

Страница 12: ...entre la placa de la cubierta y el brazo de montaje Fotocontrol Tap n de cortocircuito 1 Introduzca el fotocontrol o el tap n de cortocircuito en el recept culo y g rela a la posici n de bloqueo Figu...

Страница 13: ...se nonc de la FCC Note Cet quipement a t mis l essai et d clar conforme aux limites tablies pour un dispositif num rique de cat gorie A en vertu de l article 15 des r glements de la FCC Ces limites so...

Отзывы: