3
Cooper Lighting Solutions
IB514101EN
Installation instructions
Installation Instructions – LAS Area / Site
Figure 4.
Figure 5.
Allen Head Screws
Through bolt
Hex Head Bolt
3. Adjust slipfitter to the desired angle by loosening the
center hex bolt enough to rotate and adjust. Retighten
the center hex bolt to 120 in-lbs to secure. (Figure 4.)
ote:
N
Fixture suitable for down mount only. Do not tilt
above 45 degrees from horizontal.
4. Reinstall slipfitter cover plate via two Phillips head
screws. (Figure 2.)
5. Connect luminaire to supply wires (Figure 5.):
a. Connect supply side line voltage to black lead.
b. Connect supply side common wire to white lead.
c. Connect supply side ground wire to green lead.
7. If mounting to a horizontal tenon, reinstall the through
bolt to secure fixture to tenon. Tighten through bolt to
120 in-lbs. (Figure 6.)
Figure 6.
Pole Mount Arm
Tools Required:
•
#2 Phillips screwdriver
•
4/5/6 mm Allen wrenches
•
M19 Torque Wrench
•
M19 Open End Wrench
•
Drill (optional)
1. Remove the cover plate on the pole mount arm by
removing the four Phillips head screws and using the
pull tab labeled “open”. No need to completely remove
the four Phillips head screws, there is a rubber ring on
each screw to hold it to the cover plate. Set door aside.
(Figure 7.)
2. Align pole mount arm top hole with top hole in pole.
Align pole mount slot with bottom hole in pole
(Figure 8.)
ote:
N
Fixture suitable for down mount only. Do not install
with slot on top.
3. For round poles only – Install round plate adapter with
round side facing pole.
Figure 7.
Phillips head screw
Phillips head screw
Round plate adapter
Install washer, then split
washer, and then nut
Figure 8.
6. Remove the slipfitter through bolt and install slipfitter
onto 2-3/8” O.D. tenon. Be careful not to pinch any
wires and tighten the four Allen head set screws to 30
in-lbs. (Figure 6.)
(+) Line
(-) Common
Ground
Black
White
Green
Fixture