background image

 

LED-PAR196

LED Splash™

 

 

USER MANUAL

 

CHAUVET, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com 

2008-04-02/13:33 

Содержание LED Splash LED-PAR196

Страница 1: ...LED PAR196 LED Splash USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2008 04 02 13 33 ...

Страница 2: ...TUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 Daisy Chain Connection 7 Dipswitch Options 7 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 RETURNS PROCEDURE 10 CLAIMS 10 DMX DIPSWITCH QUICK REFERENCE CHART 11 TECHNICAL SPECIFICATIONS 12 TECHNICAL SUPPORT 12 LED PAR196 User Manual 2 2008 04 02 13 33 ...

Страница 3: ... sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure the...

Страница 4: ...lor change program with 10 selectable speeds 7 static colors 5 color pattern chase programs with adjustable speeds and sound active mode via LED BOSS COLORboss TM controller Up to 100 000 hour LED life span Master Slave mode OPTIONS Optional LED BOSS COLORboss TM controller Programmable Any universal DMX 512 controller DMX Channel Summary Ch 1 2 CHANNEL INTENSITY CONTROL OF 1 Red 2 Green 3 Blue 4 ...

Страница 5: ...ressing DMX Connectors Switch selectable voltage Fuse Power plug Green LED DMX Signal Indicator Hanging yoke 7 LED circles are controlled individually to create an unlimited range of visible colors Red LED Power Indicator LED PAR196 User Manual 5 2008 04 02 13 33 ...

Страница 6: ...y off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Liv...

Страница 7: ...ns 3 Slaves Set dipswitch 1 to the ON position and all others to the OFF position 4 You can also run the fixtures in an automatic stand alone mode by simply setting all fixtures to run as master units Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture ...

Страница 8: ...ing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide...

Страница 9: ...of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 i...

Страница 10: ...se for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage ...

Страница 11: ...5 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 ...

Страница 12: ... Watt Quantity 196 Total Red 85 Green 51 Blue 60 FUSE Main 20mm Glass 2A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION LED Splash LED PAR196 COLORboss LED BOSS Technical Support Address Service Dept 3000 N 29th Ct Hollywood...

Отзывы: