V5 Home Installation and Operation Manual
13
Note:
①
The horizontal distance between hydro box and thermal insulation water tank shall not
exceed 5m, and the vertical fall shall not exceed 3m. It is recommended to install the
water tank at lower and install the hydro box at upper.
②
If the total waterpower loss between floor heating pipeline and valves exceeds 6m,
please add floor heating engineering pump behind the solenoid valve D. There is
control interface reserved in the electric box of hydro box. Please connect wire
according to the wiring diagram on the electric box.
③
Prepare materials according to connector size and specification above. If the cutoff
valve is installed outdoors, it is recommended to use PPR fittings, thus to avoid
freezing under low temperature.
④
The hydro box shall be properly fixed before proceeding to installation of water pipes.
During installation of the connection pipe, prevent the dust or other foreign articles