V5 Home Installation and Operation Manual
15
a vertical fall of 3m to the hydro box. It can be installed indoors or outdoors, such as
balcony, rooftop or floor.
(2) The vertical thermal insulation water tank must be placed upright, with the bottom on
ground. The installing position must be firm and solid. To avoid shaking, the water tank
must be fixed onto the wall with bolts. See below for details. The weight bearing capacity
of the installing position must be considered when installing the water tank.
(3) For replenishing to water tank, supply of hot water and drainage of water tank, the tap
water pipe, hot water connector and ground drain shall be available close to the thermal
insulation water tank.
(4) Connection of inlet / outlet pipe: Th
e included safety check valve (Take care that the “→”
direction shall point toward the thermal insulation tank) shall be connected to the inlet of
water tank by using PPR pipe and be sealed with adhesive tape, as shown below.
Another end of the check valve shall be connected to the tap water. The hot water pipe
shall be connected to the outlet of water tank by using PPR pipe.
Note:
To ensure safety during use of water, the inlet and outlet of water tank must be connected with