V5 Home Installation and Operation Manual
16
a specific length of PPR pi
pe. The length “L” is calculated as below: L≥70×R
2
, in which “L” refers to
pipe length (unit: cm) and R refers to the inner radius of the pipe (unit: cm). Thermal insulation
shall be done and metal pipe shall not be used. For the first time of use, make sure that the water
tank is filled with water before connecting to the power. The water tank shall not run without water.
3.2.6.2 Setting of Water Tank Capacity
The ex-factory defaulted water tank capacity is 300L. If the actual installed water tank
capacity is smaller than 300L, setting is not needed. If the actual installed water tank capacity is
bigger than 300L, please arrange setting as below.