Air Source Heat Pump Water Heater
5
During the installation, please comply with the model mapping in the preceding
table. Otherwise, a fault may occur because the main unit mismatches the
exchanger capacity of the water tank.
Table 2-2 Unit Model and Specification
Model
CH-HP3.5SWNK
Rated Heating Capacity
(
*
)
W
3500(1800
~
4000)
Rated Input Power
(
*
)
W
850(360
~
1333)
COP
(
*
)
W/W
4.10
Load Profile
-
L
COP
DHW
(
**
)
W/W
3.17
Energy Efficiency Class
(2)
-
A
Water Heating Energy Efficiency
(2)
-
129%
Annual electricity consumption
(average climate conditions)
kWh
795
Maximum Input Power
W
1500+1500W (Electric Heater)
Outlet Water Temperature
°C
Default: 55°C, 35°C~55°C
Power Supply
-
220V-240V ~50Hz
Insulation Level
-
Ⅰ
Protection of Ingression
-
Ⅰ
PX4
Refrigerant
Name
R410A
Charge
kg
1.40
Outline Dimensions
W x D x H
mm
842×320×591
Package Dimensions
W x D x H
mm
941×371×660
Gross/Net Weight
kg
44.5/38.5
Sound Power Level
(
***
)
dB(A)
63
Operating Range
°C
-25~45°C
Notes:
①
(*)
Value obtained with the following conditions: Outdoor temperature:
20
°C
DB/15
°C
WB; Water tank temperature (start/end): 15
°C
/55
°C
.
②
(
**
) Value obtained with an air temperature of 7
°C
and a water inlet at 10
℃
,
as per EN16147, (EU) No 814/2013.