background image

 Revised: 23/08/2012 

 

Printed 

19

Printed: 20/03/2013 

W

ARRANTY 

 

DESIGNATION  OF  WARRANTOR.    This  warranty  is  extended  by  Shamic  Sheetmetal  (Aust)  Pty.  Ltd  with  respect  to 
Coonara gas heaters  
PRODUCT.  This Coonara gas heater is comprised of the heater proper (including components and firebox), fan assembly, 
speed control switch, electrical components, gas valves, seals and moving parts.  Except where specifically excluded from 
coverage hereunder, this warranty covers all components designed. 
See exclusions and qualifications below for further information on product coverage. 
WARRANTY: 

1)

 

Shamic Sheetmetal (Aust) Pty. Ltd warrants the firebox and the heat exchanger to be free of defects in materials 
and workmanship of a period of five (5) years from the date of purchase. 

2)

 

Shamic Sheetmetal (Aust.) Pty.Ltd. warrants that all other components of the unit to be free of defects in material 
and workmanship for a period of two (2) years from date of purchase, excluding door glass and decorative logs. 

3)

 

If  this  Coonara  heater  is  found  to  be  defective  in  material  or  workmanship  Shamic  will  repair  or  replace  such 
defects in the Coonara heater at Shamic’s option in accordance with Coonara’s warranty policy during the period 
on this warranty. If the defect is found not to meet the Consumer Guarantee requirements and constitutes a major 
failure, the purchaser may be able to choose to repair or replace the defective heater or part or obtain a refund. 

4)

 

Exclusions and qualifications.  This warranty is subject to the following exclusions and qualifications. 

a)

 

This  warranty  extends  only  to  the  original  consumer  purchaser,  who  has  purchased  the  heater  from  an 
authorised Coonara dealer. 

b)

 

This warranty does not apply to, and Coonara assumes no responsibility for any damages that result due 
to,  installation  or  operation  of  the  heater  not  in  accordance  with  both  the  installation  and  operation 
instructions furnished with the unit. 

c)

 

This  warranty  does  not  apply  to  any  heater  which  has  been  modified  or  damaged  in  shipping  or  by 
improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs. 

d)

 

Shamic Sheetmetal (Aust.) Pty.Ltd. does not warrant the structural performance of the heater when fuel 
products  other  than  the  specified  gas  fuels  are  used.    Flammable  liquid  fuels  are  explosive  and  should 
never be used in this product. 

e)

 

Shamic  Sheetmetal  (Aust.)  Pty.Ltd.  expressly  excludes  any  liability  hereunder  for  defects  or  damage 
caused  by  the  installation  or  of  any  components  not  expressly  authorised  and  approved  by  Shamic.    
Shamic  further  assumes  no  liability  for  defects  or  damage  caused  by  any  modification  not  expressly 
authorised  and  approved  by  Shamic.    Unauthorised  components  or  modifications  could  create  a  fire 
hazard by altering the safety design of the heater. 

f)

 

Building  Codes.    Since  building  code  requirements  vary,  users  should  determine  in  advance  whether 
there  are  any  building  code  restrictions  on  the  installation  or  use  of  the  heater.    Shamic  makes  no 
representation  of  warranty  regarding  building  code  compliance  and  shall  not  be  responsible  for 
compliance therewith. 

g)

 

Shamic  will  only  accept  claims  under  this  warranty  in  strict  accordance  with  the  conditions  set  out 
below. 

5)

 

Shamic  Sheetmetal  (Aust.)  Pty.Ltd.  shall  not  be  liable  for  any  breakages  of  glass  and  log  components,  transit 
damage or, where it can be shown that the consumer guarantee obligations as the manufacturer have been met, for 
any  claim  by  any  person  for  incidental  or  consequential  damages  caused  by  defects  in  the  Coonara  heater.  
Whether  such  damage  occurs  or  is  discovered  before  or  after  replacement  or  repair,  and  whether  or  not  such 
damage is caused by Coonara negligence.  Normal wear and tear items such as routine surface maintenance, seals 
and door glass are also excluded from this warranty. 

6)

 

Shamic goods come with guarantees that cannot be excluded under Australian Consumer Law. The purchaser is 
entitled to a replacement or a refund for a major failure and compensation for any reasonably foreseeable loss or 
damage. The purchaser is also entitled to have the goods repaired or replaced if the goods fail to be of acceptable 
quality and the failure does not amount to a major failure. 

7)

 

This warranty applies only to units purchased from an authorised dealer and the duration of this implied warranty, 
including merchantability, applicable to this Coonara heater is limited to the duration of the foregoing warranty. 

8)

 

Before Shamic Sheetmetal (Aust.) Pty.Ltd. will recognise or accept a claim under this warranty, you must provide 
proof of purchase.  On purchase of the heater, despatch your warranty card to Shamic Sheetmetal (Aust.) Pty.Ltd. 

9)

 

Your  authorised  dealer  must  be  notified  of  any  defect  in  the  heater,  for  investigation  of  the  claim.  In  the  event 
where a remedy is necessary and the claims under warranty are accepted, the purchaser may be required to return 
the goods to the authorised dealer for repair, replacement or refund. 

 

 

 
 
 
 
 

Содержание CONSOLE

Страница 1: ...OPERATING INFORMATION INSTALLATION INSTRUCTIONS Serial Number of Heater ____________ Model ___________________ Hermitage Gas Heaters ARE AUSTRALIAN OWNED MANUFACTURED BY SHAMIC SHEETMETAL SHAMIC SHEE...

Страница 2: ...vel surface Inbuilt models must be placed on AC sheeting to prevent unit from rattling Heater must be checked for scratches or dents prior to installation All glass must be fitted with a screw driver...

Страница 3: ...4 CUSTOMER OPERATING INSTRUCTIONS 6 SAFETY PRECAUTIONS SAFETY FEATURES 7 INSTALLATION INSTRUCTIONS 8 14 LOG INSTALLATION WIRING DIAGRAM 15 GAS VALVE ADJUSTMENT 16 TROUBLESHOOTING GUIDE 17 DIMENSIONS W...

Страница 4: ...al Conform to AS3100 240V 50 Hz 120 Watts Max Air Pressure Switch Aria 380 series 5471 Cut in Pressure 45 Pa Cut out Pressure 40 Pa Electrical Connection Standard Flex 2 Mt 3 Pin Plug Hermitage Freest...

Страница 5: ...n accordance with AS NZS 5601 Gas Installation Standard Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Building Codes This appliance must only be installed and servic...

Страница 6: ...ion Note At start up if the High position has been selected the heater will only ignite on the Low setting and will automatically switch to the High setting after an initial warm up period TURNING THE...

Страница 7: ...rized person who is responsible for its correct operation at the time of installation AS NZS 5601 Appliance Commissioning 9 2 The commissioning of an appliance shall take full account of special desig...

Страница 8: ...and adjust if necessary J Reassemble heater in reverse order of above connect electrical cord to correctly wired and earthed 240 volt AC power point K Operate heater check operation of heater on both...

Страница 9: ...lly over the hole 6 Fit the tapered flue dress trim wide end towards the heater over the flue outlet on top of the heater 7 Fit the inner and outer 900mm flue lengths to spigots on top of the heater 8...

Страница 10: ...surround The fascia is secured to the heater surround by 2 lugs and can be removed by lifting the fascia upward approximately 5 mm and then forward 4 Remove the 2 screws holding the fascia surround to...

Страница 11: ...nd the exhaust port at the flue terminal 2 Feed both flexible pipes down the flue cavity 3 Fix flue terminal securely to top of flue cavity and seal to prevent water entry Seal with Hi Temperature wat...

Страница 12: ...gas connection 3 Connect Gas 4 Fit the bends and short inner and outer flue pipes to the heater spigot 5 Slide the heater into position with the flue pipes protruding through the hole in the rear of t...

Страница 13: ...e flue pipes through the pre punched hole for the flue pipes on the upper left hand side 6 Locate the appliance connect gas 7 Fit the outer weather cover over the exposed heater body and screw to the...

Страница 14: ...Printed 20 03 2013 IMPORTANT The Hermitage Gas Log Heater must always be vented to the outside IMPORTANT Cut outer flue casing to ensure inner Flue exhaust pipe protrudes 50 mm above outer casing Cri...

Страница 15: ...as illustrated below to the pins located on the front and rear logs Logs should not touch the sensor or sparker Above diagram shows correct orientation of logs WIRING DIAGRAM GAS VALVE ADJUSTMENT The...

Страница 16: ...e nut clockwise to increase gas pressure Natural Gas Burner test point pressure HIGH 0 9 kPa LOW 0 48 kPa Primary air shutter adjustment fully open Freestander fully open Inbuilt Natural gas injector...

Страница 17: ...ed start and will not start until unit warms up Check wiring Install fan in correct location Remove and clean fan Unit cuts out after a period of time then cycles on and off See Room fan not operating...

Страница 18: ...ve base 250mm from right side of unit How to Make a Warranty Claim Coonara Heatcharm Arrow and Settler Heaters The full Warranty Statement for your heater is contained in the Installation and Operatin...

Страница 19: ...ressly excludes any liability hereunder for defects or damage caused by the installation or of any components not expressly authorised and approved by Shamic Shamic further assumes no liability for de...

Страница 20: ...service and check be made by a qualified person annually The fascia should be removed and the fan vacuumed annually To clean the appliance simply wipe over with a damp cloth Do not use solvents or abr...

Страница 21: ...____________________________ ADDRESS __________________________________________________________________________________________________ CITY STATE POSTCODE ____________________________________________...