background image

 Revised: 23/08/2012 

 

Printed 

5

Printed: 20/03/2013 

 
 

This appliance shall only be installed in accordance with: 

 

 

AS/NZS 5601   (Gas Installation Standard), 

 

Manufacturer’s Installation Instructions, 

 

Local Gas Fitting Regulations, 

 

Municipal Building Codes. 

 

This appliance 

must

 only be installed and serviced by an authorised person 

 
 
 
 
 
 
 
 

Please store this manual in a safe place for future reference 

 
 
 
 
 
 
 

Содержание CONSOLE

Страница 1: ...OPERATING INFORMATION INSTALLATION INSTRUCTIONS Serial Number of Heater ____________ Model ___________________ Hermitage Gas Heaters ARE AUSTRALIAN OWNED MANUFACTURED BY SHAMIC SHEETMETAL SHAMIC SHEE...

Страница 2: ...vel surface Inbuilt models must be placed on AC sheeting to prevent unit from rattling Heater must be checked for scratches or dents prior to installation All glass must be fitted with a screw driver...

Страница 3: ...4 CUSTOMER OPERATING INSTRUCTIONS 6 SAFETY PRECAUTIONS SAFETY FEATURES 7 INSTALLATION INSTRUCTIONS 8 14 LOG INSTALLATION WIRING DIAGRAM 15 GAS VALVE ADJUSTMENT 16 TROUBLESHOOTING GUIDE 17 DIMENSIONS W...

Страница 4: ...al Conform to AS3100 240V 50 Hz 120 Watts Max Air Pressure Switch Aria 380 series 5471 Cut in Pressure 45 Pa Cut out Pressure 40 Pa Electrical Connection Standard Flex 2 Mt 3 Pin Plug Hermitage Freest...

Страница 5: ...n accordance with AS NZS 5601 Gas Installation Standard Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Building Codes This appliance must only be installed and servic...

Страница 6: ...ion Note At start up if the High position has been selected the heater will only ignite on the Low setting and will automatically switch to the High setting after an initial warm up period TURNING THE...

Страница 7: ...rized person who is responsible for its correct operation at the time of installation AS NZS 5601 Appliance Commissioning 9 2 The commissioning of an appliance shall take full account of special desig...

Страница 8: ...and adjust if necessary J Reassemble heater in reverse order of above connect electrical cord to correctly wired and earthed 240 volt AC power point K Operate heater check operation of heater on both...

Страница 9: ...lly over the hole 6 Fit the tapered flue dress trim wide end towards the heater over the flue outlet on top of the heater 7 Fit the inner and outer 900mm flue lengths to spigots on top of the heater 8...

Страница 10: ...surround The fascia is secured to the heater surround by 2 lugs and can be removed by lifting the fascia upward approximately 5 mm and then forward 4 Remove the 2 screws holding the fascia surround to...

Страница 11: ...nd the exhaust port at the flue terminal 2 Feed both flexible pipes down the flue cavity 3 Fix flue terminal securely to top of flue cavity and seal to prevent water entry Seal with Hi Temperature wat...

Страница 12: ...gas connection 3 Connect Gas 4 Fit the bends and short inner and outer flue pipes to the heater spigot 5 Slide the heater into position with the flue pipes protruding through the hole in the rear of t...

Страница 13: ...e flue pipes through the pre punched hole for the flue pipes on the upper left hand side 6 Locate the appliance connect gas 7 Fit the outer weather cover over the exposed heater body and screw to the...

Страница 14: ...Printed 20 03 2013 IMPORTANT The Hermitage Gas Log Heater must always be vented to the outside IMPORTANT Cut outer flue casing to ensure inner Flue exhaust pipe protrudes 50 mm above outer casing Cri...

Страница 15: ...as illustrated below to the pins located on the front and rear logs Logs should not touch the sensor or sparker Above diagram shows correct orientation of logs WIRING DIAGRAM GAS VALVE ADJUSTMENT The...

Страница 16: ...e nut clockwise to increase gas pressure Natural Gas Burner test point pressure HIGH 0 9 kPa LOW 0 48 kPa Primary air shutter adjustment fully open Freestander fully open Inbuilt Natural gas injector...

Страница 17: ...ed start and will not start until unit warms up Check wiring Install fan in correct location Remove and clean fan Unit cuts out after a period of time then cycles on and off See Room fan not operating...

Страница 18: ...ve base 250mm from right side of unit How to Make a Warranty Claim Coonara Heatcharm Arrow and Settler Heaters The full Warranty Statement for your heater is contained in the Installation and Operatin...

Страница 19: ...ressly excludes any liability hereunder for defects or damage caused by the installation or of any components not expressly authorised and approved by Shamic Shamic further assumes no liability for de...

Страница 20: ...service and check be made by a qualified person annually The fascia should be removed and the fan vacuumed annually To clean the appliance simply wipe over with a damp cloth Do not use solvents or abr...

Страница 21: ...____________________________ ADDRESS __________________________________________________________________________________________________ CITY STATE POSTCODE ____________________________________________...

Отзывы: