![Cookson Speedline Technologies Electrovert Bravo 8105 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/cookson/speedline-technologies-electrovert-bravo-8105/speedline-technologies-electrovert-bravo-8105_preventive-maintenance-manual_2660435053.webp)
2-9317-373-00-0
Bravo™ 8105 Preventive Maintenance Guide
5-39
5
Monthly Preventive
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance Procedures
Electrical Cabinet Filters
Introduction
Electrical Filters are located in the cabinets on the front of the Bravo™ 8105. It is
necessary to keep the filters clean so that air flow is not impeded through the
electrical cabinets. There are two (2) filters located on the Bravo™ 8105: one on
the Load End and one on the Front center of the machine. Clean the filters
monthly — approximately every 170 hours of operation.
Tools or Materials
Needed
• Liquid All–Purpose Cleaner
Procedure
Step
Action
1
Access the filter from the outside of the cabinet. Refer to Figure 5–
2
Remove the filter by first removing the black plastic cover. There are
no hardware connectors. Press the sides of the cover inward to
release it from the machine. Refer to Figure 5–2.
3
Soak the filter in soapy water and allow them to dry before
replacing.
4
Replace the plastic cover.