TROUBLESHOOTING PROCESS

I

f your Water Witch is not operating correctly upon installation or you suspect a fault after 

years of reliable service, follow the steps outlined below then refer to the table of faults to 

identify the issue:

Return the Control Box settings to Test Mode as per the instructions on Page 13.   

ENSURE THE POWER SUPPLY IS TURNED OFF AND THE WATER WITCH POWER 

LEAD IS REMOVED FROM THE POWER SUPPLY WHEN REMOVING THE CONTROL 

BOX COVER.

 Refer to the following tables to identify the fault being experienced and the 

action required to remedy the fault.

WATER WILL NOT TURN ON:

Light Display

Possible Fault

Remedy

ON & SENSE

Sensor – debris may be 

impeding function

Remove screws & disc plate 

from bottom of Sensor.  Remove 

ball to clean the inside of Sensor 

and LEDs

Sensor plug not inserted 

correctly into control box

or 

Individual sensor wires have 

been damaged or removed from 

sensor plug

Ensure sensor plug is inserted 

into correct port at base of 

Control Box, inspect sensor plug 

for damage and check wires are 

connected as follows:

Sensor may need to be replaced if these actions do not correct fault

YELLOW

GREEN 

BLACK

RED 

Содержание WaterWitch

Страница 1: ...Product Support Guide Full Electrical Certi cation Inside Outside use ESV160204 C Tick Approval N11116...

Страница 2: ...pes were developed and tested in my shed at home until we had a suitable production model After a few years of production further tweaks and improvements were decided upon The Water Witch was born For...

Страница 3: ...x installation Page 05 Sensor installation Page 06 Solenoid installation Page 08 Alternative installation options Page 10 Start up process Page 12 Test and time delay modes Page 13 Operation of indica...

Страница 4: ...and must be returned upon its request Template updated August 2014 WaterMark Certificate Of Conformity Level 1 This is to certify that Nymet Australia Pty Ltd ABN Head Office Address 1 53 Stanbel Road...

Страница 5: ...ficient overflow provisions to avoid a potential flooding event The Water Witch may not be suitable for installations where the water source is connected to a pressure pump Confirm high and low pressu...

Страница 6: ...ONTROL BOX WS345 Water Witch Control Box SENSOR WS355 Water Witch Sensor Only 5m WS356 Water Witch Sensor Only 20m WS357 Water Witch Sensor Only 30m WS358 Water Witch Sensor Only 40m WS359 Water Witch...

Страница 7: ...least 1 2m above ground level and ensure a consistent power source is within reach of the Control Box power lead The Control Box is approved for indoor and outdoor use However locating the Control Box...

Страница 8: ...the Sensor As the ball intersects the light beam at the top of the Sensor the Control Box recognises the full water level Instead of stopping the flow immediately the TIME DELAY MODE then overfills th...

Страница 9: ...suction and return trench and elbowed up within the equipment area THESE PIPES MUST BE LEVEL TO AVOID AIR LOCKS which will affect flow and performance A 50mm cap is provided to cover the sensor pipe h...

Страница 10: ...r INSTALLATION PROCESS AND CONSIDERATIONS The Solenoid flow is one directional ENSURE THE SOLENOID FLOW DIRECTIONAL ARROW IS POINTED IN THE SAME DIRECTION AS THE WATER FLOW The Solenoid has a 20mm mal...

Страница 11: ...a hard connection An air gap is required to ensure the water from the project cannot contaminate the water source THE FILL FLOW RATE MUST NOT EXCEED THE RATE THE BALNCE LINE TRANSFERS WATER INTO THE P...

Страница 12: ...he Sensor end cap Run the Sensor cable through appropriately sized conduit to ensure the Sensor can be accessed for serviceability and replaced if required Small debris capable of affecting sensor per...

Страница 13: ...kely result in severe pump equipment and site damage The water level in the trough may increase dramatically during a significant rainfall event or heavy bather load The trough capacity above the mini...

Страница 14: ...ate full water level The ON and SENSE lights should flash in unison every 2 4 seconds STEP 5 Turn the Sensor around the right way up to simulate low water level The ON light should continue to flash e...

Страница 15: ...L cycle The four time delay settings are controlled by the position of dip switches inside the bottom right corner of the Control Box STEP 8 TURN THE POWER SUPPLY OFF AND UNPLUG THE WATER WITCH POWER...

Страница 16: ...t the correct height ON light is flashing every 2 4 seconds and the FILL light is solid The Water Witch is in TEST MODE and is adding water because it believes the water level is low ON and FILL light...

Страница 17: ...following tables to identify the fault being experienced and the action required to remedy the fault WATER WILL NOT TURN ON Light Display Possible Fault Remedy ON SENSE Sensor debris may be impeding f...

Страница 18: ...he flow directional arrow on the Solenoid is pointing in the same direction as supply flow Reinstall if required Solenoid wire is damaged or does not have a positive connection to control box Ensure t...

Страница 19: ...most likely too high Water pressure is too high Install a Pressure Limiting Valve between supply tap Solenoid to reduce pressure WATER WILL NOT TURN OFF Be aware there is a tiny spring and rod inside...

Страница 20: ...plate from bottom of Sensor Remove ball to clean the inside of Sensor Sensor or Control Box has failed Return Control Box to Test Mode and complete the following to confirm fault Hold Sensor in uprig...

Страница 21: ...are corroded damaged or blown There are markings caused by water ingress You will most likely need to replace the Control Box if you are experiencing any of the above faults If the Control Box housin...

Страница 22: ...trol Box as required Annually Remove the solenoid pre filter to clear any debris or contaminant Maintenance checks should be conducted more regularly for commercial applications Product Water Witch El...

Страница 23: ...ditions which may impede or obstruct the correct functioning of the unit Warranty claims are to be lodged at www cookeindustries com au warranty Please note the user must submit the serial number and...

Страница 24: ...Cooke Industries P 1300 652 076 E info cookeindustries com au cookeindustries com au...

Отзывы: