15
TROUBLESHOOTING PROCESS
I
f your Water Witch is not operating correctly upon installation or you suspect a fault after
years of reliable service, follow the steps outlined below then refer to the table of faults to
identify the issue:
Return the Control Box settings to Test Mode as per the instructions on Page 13.
ENSURE THE POWER SUPPLY IS TURNED OFF AND THE WATER WITCH POWER
LEAD IS REMOVED FROM THE POWER SUPPLY WHEN REMOVING THE CONTROL
BOX COVER.
Refer to the following tables to identify the fault being experienced and the
action required to remedy the fault.
WATER WILL NOT TURN ON:
Light Display
Possible Fault
Remedy
ON & SENSE
Sensor – debris may be
impeding function
Remove screws & disc plate
from bottom of Sensor. Remove
ball to clean the inside of Sensor
and LEDs
Sensor plug not inserted
correctly into control box
or
Individual sensor wires have
been damaged or removed from
sensor plug
Ensure sensor plug is inserted
into correct port at base of
Control Box, inspect sensor plug
for damage and check wires are
connected as follows:
Sensor may need to be replaced if these actions do not correct fault
YELLOW
GREEN
BLACK
RED