![CONVECTAIR CALYPSO 7826 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/convectair/calypso-7826/calypso-7826_installation-and-user-manual_2659212009.webp)
9
-
CONVECTAIR
recommends that devices be installed by a qualified
electrician, in accordance with applicable national and local codes.
- The device must be connected to a 240 volt, 60 cycle circuit.
Disconnect the power before making any connections to avoid
electric shock or damage to the device. If you are using a
programming system, be sure to shut off ALL electric heating circuits
in the house.
- To avoid short circuits, turn off the power at the electrical panel
before any installation or repair.
- If the power supply wires of the device are damaged, they must be
replaced by the manufacturer, its after-sales service, or a similarly
qualified person in order to prevent danger.
- The purple wire is used if the device is connected to the
CONVECTAIR Programmer. Grounding the pilot wire (purple wire)
can cause serious damage to internal circuits. Never connect the
pilot wire (purple wire) to the power wire.
- This unit must be grounded. Ensure the green wire from the heater is
connected with a ground wire.
!
1 Turn off the power to the heater and to all devices connected to the pilot wire
before opening.
2 Complete the electrical connection according to the connections diagrams below.
3 Secure the heater to the wall bracket before turning it on. Never operate the device
when it is not attached to the wall bracket.
Electrical Connection
HEA
TER
B
B
R
R
G
G
G
G
P
P
L1
L1
L2
L2
PW
HEA
TER
PO
W
ER LINE
PO
W
ER LINE
B=BLACK R=RED G=GREEN P=PURPLE L1=LINE 1 L2=LINE 2 G=GROUND PW=PILOT WIRE
WITH the use of pilot wire
WITHOUT the use of pilot wire
CONNECTION DIAGRAMS
The purple wire is only used if the device is connected to the CONVECTAIR Programmer.