PRODUCT INSTALLATION
ChlorMaker IL is equipped with a 110/220 VAC Auto-Sensing Power Supply allowing ChlorMaker IL to be installed
on almost any spa with a 24 Hour Circulation Pump. Please follow the installation instructions below.
1. Prepare Spa For Installation:
Shut down main power to spa and drain water completely. Open access
panel to the spa exposing the spas plumbing area.
2. Find Power Supply Location & Route Power Supply Cable (DO NOT FASTEN POWER SUPPLY TO THE
CABLE OR TO POWER SOURCE AT THIS POINT):
Find the power source location and rout the power sup-
ply cable from the control panel to the power source. The black cable clips can be used to secure the cable
in place. IMPORTANT: Make sure the power source is GFI Protected and is protected by a weather protec
-
tive cover. Single Gang and Double Gang weather protective covers can be purchased at any local hardware
store. Please see weather protective cover example in the picture below.
3. Find Skirting Location For Control Panel:
Find a convenient location on the skirting just below the fiber
-
glass lip of the spa. It is important that the location is near the access panel to the spa compartment allowing
the cell cable to be routed appropriately. Rout the Cell Cable from the control panel through the spas access
panel. Most access panels have a small gap at the bottom of the panel. See Picture Below.