TROUBLE SHOOTING
It is always a good idea to revisit the user manual to make sure installation or maintenance steps were not over-
looked before referring to the trouble shooting section.
Problem
Possible Causes
Corrective Action
Consistently Low
Chlorine
Power level too low
Increase the power level
Plates need cleaning
Soak the unit in Vinegar for 30 minutes
Low salt level
Adjust the salt level as necessary - use test strips
Large bather load
Additional chlorine or shock may be needed
Just doesn’t keep up
Remove organic material, such as leaves, etc.
Clean the filter
Remove Phosphates
Shock the water
Consistently High
Chlorine
Power level too high
Lower the power level
No Chlorine (Solid
RED
&
GREEN
Lights)
Salt level may be too high
and engaged the automat-
ic shut down feature.
Dilute the spa water by draining some of the spa water and
refilling with fresh water.
Plates Are Dirty
With White Or
Scale Build Up
Hard water, high calcium
and minerals in water.
Soak the cell in vinegar or diluted acid for 30 minutes. Re
-
duce calcium level in water.
BOOST MODE
Boost Mode is designed to replenish chlorine that was just used during the last spa use. Activating Boost Mode will
take ChlorMaker IL out of regular production mode or standby mode and re-start the production of chlorine accord
-
ing to the following table. To activate Boost Mode simply press the Boost Mode Button. The Salt Light will begin
flashing indicating that ChlorMaker IL is engaged in Boost Mode.
Power
Level
Normal Time
(Minutes)
Boost Mode Time
(Minutes)
1
2
8
2
7.5
30
3
15
60
4
30
120
5
45
180
6
60
180
7
90
180
8
120
180
9
150
180
10
180
180