6-12
Serial communications
6.4
Serial communications modes
The
UD70
has eleven communication modes as follows:
•
4-wire and 2-wire standard
ANSI
slave
•
High-speed parameter transfer
•
Programmable master/slave modes
•
User modes
•
I/O Box mode
The available options are as follows (see Set-up parameters in Chapter 10
Parameters for details of the actual parameters):
Mode 1 Standard 4-wire
RS485
using
ANSI
slave protocol (default).
Mode 2 Master mode
In this mode, data is taken from the defined parameter, scaled to
±
16000
then continuously transmitted out to a slave Drive. The slave unit can be
an MD29, a Unidrive standard communications option module, a Mentor II
Drive, a CDE Drive or another UD70.
Mode 3 Slave mode
In this mode, data is received from the serial port and is scaled by the value
of the scaling set-up parameter before being placed in the destination
parameter.
Mode 4 Cascade mode
With this mode, a defined parameter is transmitted to a remote Drive unit
(no scaling) and received data is placed into the destination parameter.
The data is not scaled.
The transmitting unit and/or receiving unit can be either another
UD70
,
MD29
, Unidrive with standard communications option module, or a Mentor II
Drive.
This mode is typically used in wire-drawing type applications – the first
Drive is given a speed reference from an external source (eg. a
potentiometer). Mode 4 communications are used to pass that reference
down to the next Drive on the line which uses an Applications Option to
receive the data and apply draw. That Drive then passes the new reference
down to the next Drive, etc.
Mode 5 2-wire
RS485
Using standard
ANSI
slave protocol. Note that
RS232
is not 2-wire
RS485
.