Parameters
10.2 Virtual
parameters
Virtual parameters are special parameter which are not part of the standard
parameter-set of the Drive. Virtual parameters exist only in the
UD70
and
are used for the following:
•
Accessing values not present as standard Drive parameters
(eg. encoder counters)
•
Accessing Drive parameters at a faster rate
•
Accessing Drive parameters at an increased resolution
•
Accessing
UD70
parameters such as Timer/counter Unit control
parameters, I/O Box data, etc
Virtual parameters can be accessed by a DPL program or by serial
communications. The virtual menus are explained in the following order:
90, 91, 70 ~ 73, 85, 86, 88, 80
Menu 90
General parameters
Note that update rate codes L2 and L3 in the following table are explained at
the end of the table. Where no update rate is shown, it does not apply.
Parameter
Description
#90.01
Main encoder/resolver position (RO)
#90.03
Auxiliary encoder position (RO)
#90.05
Used only when a
SIN
-
COS
encoder option module is fitted in the
Drive and the Drive software is version 3 or higher
Number of revolutions of a
SIN
-
COS
encoder (RO)
Update rate: L2
#90.06
Used only when a
SIN
-
COS
encoder option module is fitted in the
Drive and the Drive software is version 3 or higher
Position of a
SIN
-
COS
encoder (RO)
#90.6 indicates only the eight least significant bits.
Update rate: L2
#90.10
Drive mode identifier (RO)
Codes are as follows:
16
Open Loop
17
Closed Loop Vector
18
Servo
#90.11
Drive status and control word
#90.11 indicates the value of the Drive status parameter (#10.40).
The control word can be written to #90.11 as shown in the
following table.