5.5 Freeze
inputs
(terminals 48, 49)
If the
Freeze
function is required, a UD70
large option module
must be fitted
in the Drive in order to read the
freeze
position, and pass the data to the
system controller or PLC. The initiating signal for the
freeze
function must
be applied to terminals 48 and 49 on the UD52.
Related UD70 parameters
_
Q20%.5 Control word (bit 5)
Set at 1 for the current absolute positions of the feedback and reference
encoders to be entered in
_Q21%
and
_Q22%
when the
Freeze
input is
activated.
_Q20%.5
is reset to zero when the values have been entered.
_
Q21% Feedback-encoder freeze value
Units Encoder lines
Range –2
31
to 2
31
Reset H = S/V S = N/A P = N/A
_
Q22% Reference-encoder freeze value
Units Encoder lines
Range –2
31
to 2
31
Reset H = S/V S = N/A P = N/A
5.6 Further setting up
Refer to
Parameters descriptions
in Chapter 6
Related Parameters
for setting
up the following:
Function Parameter
Disable interpolation 16.17
Disable updating the position parameters when reading 16.11