UD52 User Guide
Issue code: 52nu3
11
4.3 Serial
communications
When absolute positioning is required, connect terminals 46, 47
Serial
communications
to the appropriate connections on the encoder.
The serial link allows the Drive (at power-up) to interrogate the
SIN
-
COS
encoder in order to determine the initial absolute position of the encoder
shaft. When the interrogation is completed, the serial link is disabled.
If the serial link fails, the Drive will trip, showing trip code
SEP EC
.
When a
SIN
-
COS
encoder is used with a Drive operating in the Closed-loop
Servo mode, absolute-position and phase-offset information is always
required. In the Closed-loop Vector mode for controlling an induction
motor, absolute-position and phase-offset information are optional.
When this information is not required, serial communications connections to
the encoder do not need to be made. In this case, set parameter
16.16
S
IN
-
COS
encoder – serial comms disable
at 1 (otherwise a
SEP EC
trip will occur
at power-up).
Operating mode Terminals
46, 47
Parameter
16.16
Closed-loop Servo mode
Closed-loop Vector mode when absolute-position
information is required
Connect to serial comms. port
of
SIN
-
COS
encoder
0
Closed-loop Vector mode when absolute-position
information is
not
required
No connections 1