Gsm Advanced Manual - 31
31
31
31
12.6 Set and latch temperature control
A specific SMS command is available to activate temperature control (or directly turn off working
in on/off mode and regulator is disabled) and keep active even after a blackout recovery.
Default settings can be modified by means of GsmSuite or by supervisors issuing the following
SMS:
+4,256,,SmsCommand,,,,,LogText
12.6.1 SmsCommand
The text that will be associated to this command when received within an SMS coming from
authorized users. Must be a single word, up to 14 characters long.
Default is
run
12.6.2 LogText
This text will be included in the log string issued when trace is active.
Default is
reg on! request
12.6.3 Example
+4,256,3,boilerrun,,,,,,boiler on and latch
Set SMS command to “boilerrun” and log text “boiler on and latch”
12.6.4 Confirmation
Once Phonebook edit has been successfully done, device will send back an SMS specifying
assigned index, name and 7 markers to specify which fields are defined (
*
) and which don’t (
-
):
256,boilerrun,*----*