5
W415-0162 / E / 03.05.04
MAINTAIN THESE MINIMUM CLEARANCES TO
COMBUSTIBLES:
A.
6"
B.
6"
C.
2"
*
N
O ADDITIONAL FLOOR PROTECTION IS REQUIRED
MINIMUM
20"
FROM STOVE TOP TO CEILING
6"
TO SINGLE WALL CONNECTOR
1"
TO DIRECT VENT AND B
-
VENT
*
AT A DISTANCE OF
2"
FROM THE WALL
,
ACCESS TO THE BLOWER
SWITCH
,
ON
-
OFF SWITCH OR T H E BLOWER POWER C O R D MAY NOT
BE PRACTICAL
.
A terminal shall not terminate directly above a
sidewalk or paved driveway which is located
between two single family dwellings and serves
both dwellings. Local codes or regulations may
require different clearances.
Do not allow the inside liner to bunch up on horizontal
or vertical runs and elbows. Keep it pulled tight. A 1-1/
4" air gap all around between the inner liner and outer
stove pipe is required for safe operation. Use a firestop
when penetrating interior walls, floor or ceiling.
Provide adequate ventilation and combustion air.
Provide adequate accessibility clearance for servicing
and operating the stove.
Never obstruct the front opening of the stove.
As long as clearance to combustibles is kept within the
required distances, the most desirable and beneficial lo-
cation for a Continental stove is in the centre of a building,
thereby allowing the most efficient use of the heat created.
The location of windows, doors and the traffic flow in the
room where the stove is to be located should be consid-
ered. If possible, you should choose a location where the
vent will pass through the house without cutting a floor or
roof joist.
FIGURE 3
FIGURE 2 - SHOWN WITH OPTIONAL FRONT INSTALLED
LOCATION & CLEARANCES
CDVS600 AND CS600
NOTE: The total width of the stove is increased to 39" width with the
optional side shelves attached.