Continental Fireplaces CDCS600-P Скачать руководство пользователя страница 5

5

W415-0162 / E / 03.05.04

MAINTAIN THESE MINIMUM CLEARANCES TO
COMBUSTIBLES:

A.

6"

B.

6"

C.

2"

*

N

O ADDITIONAL FLOOR PROTECTION IS REQUIRED

MINIMUM

 20" 

FROM STOVE TOP TO CEILING

6"

TO SINGLE WALL CONNECTOR

1"

TO DIRECT VENT AND B

-

VENT

*

AT A DISTANCE OF

 2" 

FROM THE WALL

,

ACCESS TO THE BLOWER

SWITCH

,

ON

-

OFF SWITCH OR T H E BLOWER POWER C O R D MAY NOT

BE PRACTICAL

.

A terminal shall not terminate directly above a
sidewalk or paved driveway which is located
between two single family dwellings and serves
both dwellings. Local codes or regulations may
require different clearances.

Do not allow the inside liner to bunch up on horizontal
or vertical runs and elbows. Keep it pulled tight. A 1-1/
4" air gap all around between the inner liner and outer
stove pipe is required for safe operation. Use a firestop
when penetrating interior walls, floor or ceiling.

Provide adequate ventilation and combustion air.

Provide adequate accessibility clearance for servicing

and operating the stove.

Never obstruct the front opening of the stove.

As long as clearance to combustibles is kept within the
required distances, the most desirable and beneficial lo-
cation for a Continental stove is in the centre of a building,
thereby allowing the most efficient use of the heat created.
The location of windows, doors and the traffic flow in the
room where the stove is to be located should be consid-
ered. If possible, you should choose a location where the
vent will pass through the house without cutting a floor or
roof joist.

FIGURE 3

FIGURE 2 - SHOWN WITH OPTIONAL FRONT INSTALLED

LOCATION & CLEARANCES

CDVS600 AND CS600

NOTE: The total width of the stove is increased to 39" width with the

optional side shelves attached.

Содержание CDCS600-P

Страница 1: ...ller service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOU...

Страница 2: ...he same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near...

Страница 3: ...orkmanship and material for life subject to the following conditions During the first 10 years WOLF STEEL Ltd will replace or repair the defective parts at our option free of charge From 10 years to l...

Страница 4: ...installation of a fireplace insert or gas log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installati...

Страница 5: ...forsafeoperation Useafirestop when penetrating interior walls floor or ceiling Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the...

Страница 6: ...ertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carboning U...

Страница 7: ...7 W415 0162 E 03 05 04 FIGURE 8...

Страница 8: ...ns and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10 ft...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...aulking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield sh...

Страница 11: ...ent non combustible strapping to maintain the 1 clearance from combustibles FIGURE 23 FIGURE 24 This application occurs when venting through a roof Installation kits for vari ous roof pitches are avai...

Страница 12: ...the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto th...

Страница 13: ...cept a standard matte black 7 stove pipe and the Con tinental decorative brass band standard with the GS 150KT Both are available from your Continental dealer Attach the B Vent label shown below in th...

Страница 14: ...r 1 2 type L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to the flex connec tor DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...d at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermost...

Страница 17: ...ill quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a norm...

Страница 18: ...FF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all wi...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...ER 37 GD222 TERMINAL ASSEMBLY 38 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 39 W500 0077 FIRESTOP WALL PLATE 40 W020 0032 HARDWARE 41 BRTC7 BRASS TRIM COLLAR 42 BM6724 24 STOVE PIPE 7 DIAMETER 43 W010 030...

Страница 21: ...21 W415 0162 E 03 05 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ing no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper...

Страница 23: ...free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or...

Страница 24: ...24 W415 0162 E 03 05 04...