Continental Fireplaces CDCS600-P Скачать руководство пользователя страница 20

20

W415-0162 / E / 03.05.04

Contact your dealer for questions concerning prices and
availability of replacement parts. Normally all parts can be
ordered through your Continental dealer or distributor.
When ordering replacement parts always give the follow-
ing information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER OF FIREPLACE

2.  I

NSTALLATION DATE OF FIREPLACE

3.  P

ART

 N

UMBER

4.  D

ESCRIPTION O F PART

5.  F

INISH

FOR WARRANTYREPLACEMENTPARTS

,

A PHOTOCOPYOF THE

ORIGINAL INVOICE WILL BE REQUIREDTO HONOUR THE CLAIM

.

REPLACEMENTS

*

IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED

.

FOR

FURTHER INFORMATION

,

CONTACT YOUR

 C

ONTINENTAL

DEALER

.

#

PART #

DESCRIPTION

1

W135-0209

LOG #1

2

W135-0082

CHARCOAL PIECE (LOG #2)

3

W135-0076

LOG #3

4

W135-0210

LOG #4

5

W135-0211

LOG #5

6

W135-0212

LOG #6

7

W135-0213

LOG #7

8

GL-646

LOG SET

9

W725-0035

SIT VALVE - NG

9

W725-0026

SIT VALVE - LP

10

W010-0624

BURNER

11

W455-0058

#35 BURNER ORIFICE - NG

11

W455-0059

#53 BURNER ORIFICE - LP

11

W455-0065

#45 BURNER ORIFICE - NG

11

W455-0050

#55 BURNER ORIFICE - LP

12

W010-0800

PILOT ASSEMBLY  - NG

12

W010-0801

PILOT ASSEMBLY  - LP

13

W455-0069

PILOT INJECTOR - NG

13

W455-0067

PILOT INJECTOR - LP

14

W680-0005

THERMOCOUPLE

15

W680-0004

THERMOPILE

16*

W290-0029

PILOT GASKET

17

W357-0001

PIEZO IGNITOR

18*

W361-0016

GLOWING EMBERS

19*

W550-0001

CHARCOAL EMBERS

20*

W573-0008

HIGH TEMPERATURE SEALANT

21*

W385-0131

CONTINENTAL  LOGO

22

W390-0001

LATCH

23*

W660-0009

ON/OFF SWITCH

24

W690-0002

THERMODISC

25*

W380-0002

VARIABLE SPEED SWITCH KNOB

26

KB-35

VARIABLE SPEED SWITCH

27

GZ-552

REPLACEMENT BLOWER

28

W135-0069

_

SIDE (LEFT OR RIGHT)

29

W135-0073

_

TOP

30

W135-0068

_

LEG

EA

.

31

W135-0074

BASE

PAINT FINISH ONLY

32

W010-0459

ADAPTOR

C

/

W SPILL SWITCH

33

W660-0006

SPILL SWITCH

34

W080-0405

SPILL SWITCH BRACKET

35 GD175  -  WALL TERMINAL KIT

36

BM6790

90°    ELBOW - 7" DIAMETER

37

GD222

TERMINAL ASSEMBLY

38

BM67ADJ

30" TO 53"  ADJUSTABLE PIPE - 7" DIA

39

W500-0077

FIREST OP / WALL PLATE

40

W020-0032

HARDWARE

41

BRTC7

BRASS TRIM COLLAR

42

BM6724

24" STOVE PIPE - 7" DIAMETER

43

W010-0300

10' ALUMINUM FLEX LINER 

C

/

W SPACERS

  - 4" DIA

44

W025-0001

DECORATIVE BRASS BAND

46 GD180  -  PERISCOPE TERMINAL KIT

36

BM6790

90°    ELBOW - 7" DIAMETER

45

GD201

PERISCOPE

38

BM67ADJ

30" TO 53"  ADJUSTABLE PIPE - 7" DIA

49

W500-0077

FIREST OP / WALL PLATE

40

W020-0032

HARDWARE

41

BRTC7

BRASS TRIM COLLAR

42

BM6724

24" STOVE PIPE - 7" DIAMETER

43

W010-0300

10' ALUMINUM FLEX LINER 

C

/

W SPACERS

  - 4" DIA

44

W025-0001

DECORATIVE BRASS BAND

GD110  -  1/12 TO 7/12 PITCH

46

W010-0569

AIR TERMINAL

47

W120-0036

VERTICAL CAP

48

W010-0567

ROOF SUPPORT

49

W170-0063

STORM COLLAR

50

W263-0054

ROOF FLASHING

GD111 - 8/12 TO 12/12 PITCH

46

W010-0569

AIR TERMINAL

47

W120-0036

VERTICAL CAP

48

W010-0567

ROOF SUPPORT

49

W170-0063

STORM COLLAR

50

W263-0055

ROOF FLASHING

GD112 - FLAT ROOF

46

W010-0569

AIR TERMINAL

47

W120-0036

VERTICAL CAP

48

W010-0567

ROOF SUPPORT

49

W263-0056

ROOF FLASHING

50

W170-0063

STORM COLLAR

51*

W690-0001

MILLIVOLT THERMOSTAT

52*

W690-0010

REMOTE CONTROL - 

ADVA N TAGE

52*

W690-0011

REMOTE CONTROL - 

ADVANTAGE PLUS

53*

W300-0041

WINDOW GLASS

54*

W562-0031

GLASS GASKET

55

GS830-G

GOLD TRIVET

55

GS830-K

BLACK TRIVET

55

GS830-C

CHROME TRIVET

56*

GDSLL-KT

LEVELING / SECURING KIT

57

GS-64KT

BLOWER KIT

58*

GDS-786KT

DECORATIVE BRICK PANEL

59

F_A

**

ART DECO FRONT

60

F_E

**

EARLY AMERICAN FRONT

61

F_P

**

PANORAMIC FRONT

62*

W175-0138

CONVERSION KIT - 

NG

-

LP

62*

W175-0139

CONVERSION KIT - 

LP

-

NG

63*

BM6745

45°   ELBOW

64

GD-301

HEAT GUARD

65*

W175-0001

4" COUPLER

45

GD-201

PERISCOPE

66*

GDSRP-KT

RESTRICTOR KIT

67

GS-150KT

ADAPTOR KIT

44

W025-0001

DECORATIVE BRASS BAND

COMPONENTS COMMON TO BOTH UNITS:

CS600 COMPONENTS

TERMINAL KITS

ROOF TERMINAL KITS

ACCESSORIES:

CDVS600 ACCESSORIES

CS600 ACCESSORIES

BLUE

-

B

BLACK

-

K

GREEN

-

F

BROWN

-

N

ALMOND

-

S

**

FOR AVAILABLE PORCELAIN COLOURS

,

ADD THESE LETTERS T O THE BASE PART

NUMBER

:

Содержание CDCS600-P

Страница 1: ...ller service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOU...

Страница 2: ...he same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near...

Страница 3: ...orkmanship and material for life subject to the following conditions During the first 10 years WOLF STEEL Ltd will replace or repair the defective parts at our option free of charge From 10 years to l...

Страница 4: ...installation of a fireplace insert or gas log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installati...

Страница 5: ...forsafeoperation Useafirestop when penetrating interior walls floor or ceiling Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the...

Страница 6: ...ertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carboning U...

Страница 7: ...7 W415 0162 E 03 05 04 FIGURE 8...

Страница 8: ...ns and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10 ft...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...aulking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield sh...

Страница 11: ...ent non combustible strapping to maintain the 1 clearance from combustibles FIGURE 23 FIGURE 24 This application occurs when venting through a roof Installation kits for vari ous roof pitches are avai...

Страница 12: ...the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto th...

Страница 13: ...cept a standard matte black 7 stove pipe and the Con tinental decorative brass band standard with the GS 150KT Both are available from your Continental dealer Attach the B Vent label shown below in th...

Страница 14: ...r 1 2 type L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to the flex connec tor DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...d at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermost...

Страница 17: ...ill quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a norm...

Страница 18: ...FF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all wi...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...ER 37 GD222 TERMINAL ASSEMBLY 38 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 39 W500 0077 FIRESTOP WALL PLATE 40 W020 0032 HARDWARE 41 BRTC7 BRASS TRIM COLLAR 42 BM6724 24 STOVE PIPE 7 DIAMETER 43 W010 030...

Страница 21: ...21 W415 0162 E 03 05 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ing no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper...

Страница 23: ...free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or...

Страница 24: ...24 W415 0162 E 03 05 04...

Отзывы: