Continental Fireplaces CDCS600-P Скачать руководство пользователя страница 3

3

W415-0162 / E / 03.05.04

CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized

ISO 9001 : 2000 Quality Assurance Certificate.

CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure
that you, the customer, receives the quality product that you expect from WOLF STEEL Ltd..

CONTINENTAL GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY

The  following  materials  and  workmanship  in  your  new  CONTINENTAL  gas  fireplace  are

warranted against defects for as long as you own the fireplace. This covers: combustion chamber,
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
only),  gold  plated  parts  against  tarnishing,  porcelainized  enamelled  components  and  aluminium
extrusion trims.

Electrical  (110V  and  millivolt)  components  and  wearable  parts  such  as  blowers,  gas  valves,

thermal  switch,  switches,  wiring,  remote  controls,  igniter,  gasketing,  and  pilot  assembly  are
covered and WOLF STEEL LTD. will provide replacement parts free of charge during the first
year of the limited warranty.

Any labour related to warranty repair is not covered.

CONDITIONS AND LIMITATIONS

WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on

the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an authorized CONTINENTALdealer and is subject to the following conditions and
limitations:

This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.

The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the

product and all local and national building and fire codes.

This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this

warranty.

This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel

parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.

WOLF STEEL Ltd. warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years WOLF STEEL Ltd.

will replace or repair the defective parts at our option free of charge. From 10 years to life, WOLF STEEL LTD. will provide replacement burners at 50% of the current retail price.

In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in

accordance with the operation instructions and under normal conditions.

After the first year, with respect to this President's Limited Lifetime Warranty,  WOLF STEEL LTD. may, at its discretion, fully discharge all obligations with respect to this warranty by refunding

to the original warranted purchaser the wholesale price of any warranted but defective part(s).

WOLF STEEL Ltd. will not be responsible for installation, labour, or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this

warranty.

Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, WOLF STEEL’S responsibility under this warranty is defined as above and it shall not in any event

extend to any incidental, consequential or indirect damages.

This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect to this

product, its components or accessories are excluded.

WOLF STEEL Ltd. neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. WOLF STEEL Ltd. will not be responsible

for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting
configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component  due to water, weather damage, long periods of dampness, condensation, damaging chemicals

or cleaners will not be the responsibility of WOLF STEEL Ltd.

The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card

must be returned within fourteen days to register the warranty.

WOLF STEEL Ltd. reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.

ALL SPECIFICATIONS AND DESIGNS  ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED
TRADEMARK OF WOLF STEEL LTD.  PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.

Содержание CDCS600-P

Страница 1: ...ller service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOU...

Страница 2: ...he same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near...

Страница 3: ...orkmanship and material for life subject to the following conditions During the first 10 years WOLF STEEL Ltd will replace or repair the defective parts at our option free of charge From 10 years to l...

Страница 4: ...installation of a fireplace insert or gas log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installati...

Страница 5: ...forsafeoperation Useafirestop when penetrating interior walls floor or ceiling Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the...

Страница 6: ...ertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carboning U...

Страница 7: ...7 W415 0162 E 03 05 04 FIGURE 8...

Страница 8: ...ns and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10 ft...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...aulking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield sh...

Страница 11: ...ent non combustible strapping to maintain the 1 clearance from combustibles FIGURE 23 FIGURE 24 This application occurs when venting through a roof Installation kits for vari ous roof pitches are avai...

Страница 12: ...the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto th...

Страница 13: ...cept a standard matte black 7 stove pipe and the Con tinental decorative brass band standard with the GS 150KT Both are available from your Continental dealer Attach the B Vent label shown below in th...

Страница 14: ...r 1 2 type L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to the flex connec tor DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...d at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermost...

Страница 17: ...ill quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a norm...

Страница 18: ...FF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all wi...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...ER 37 GD222 TERMINAL ASSEMBLY 38 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 39 W500 0077 FIRESTOP WALL PLATE 40 W020 0032 HARDWARE 41 BRTC7 BRASS TRIM COLLAR 42 BM6724 24 STOVE PIPE 7 DIAMETER 43 W010 030...

Страница 21: ...21 W415 0162 E 03 05 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ing no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper...

Страница 23: ...free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or...

Страница 24: ...24 W415 0162 E 03 05 04...