4 NUTS

SHIPPING

BRACKET

CS600:

Maximum input is 35,000 BTU/hr for natu-

ral gas and 31,500 BTU/hr for propane. This stove is
approved for bedroom and bed-sitting room installa-
tions.

CDVS600: TOP VENT / REAR  VENT
VERTICAL TERMINATION:

 Maximum in-

put is 35,000 BTU/hr for natural gas and 31,500 BTU/hr
for propane. Maximum output for natural gas is 27,300
BTU/hr at an efficiency of 78%. Maximum output for pro-
pane is 24,570 BTU/hr at an efficiency of 78%. Maxi-
mum A.F.U.E. (annual fuel utilization efficiency) rating is
72% for natural gas and 71% for propane.

REAR VENT HORIZONTAL TERMINA-
TION:

 Maximum input is 21,000 BTU/hr for natural

and propane gas. 

This application requires changing

the main burner orifice.

This stove is not approved for closet or recessed instal-
lations. It is approved for bathroom, bedroom and bed-
sitting room installations.
This stove may be installed in an aftermarket perma-
nently located, manufactured (mobile) home, where not
prohibited by local codes.

Change in flame appearance from "HI" to "LO" is more evi-
dent in natural gas than in propane. Expansion / contraction
noises during heating up and cooling down cycles are nor-
mal and to be expected.

This appliance is only for use with the type of gas indicated
on the rating plate. 

(See page 14).

 This appliance is not

convertible for use with other gases, unless a certified kit
is used.

INSTALLER:  It is your responsiblity to check off the
appropriate box on the rating plate according to the
model, venting and gas type of the unit.

Do not use abrasive cleaners to clean these parts. Buff
lightly with a clean dry cloth.
The glass is 

3

/

16

" ceramic glass available from your

Continental / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE
MATERIALS. Clean the glass after the first 10 hours of op-
eration with a recommended gas fireplace glass cleaner.
Thereafter clean as required.  DO NOT CLEAN GLASS
WHEN HOT! If the glass is not kept clean permanent dis-
colouration and / or blemishes may result.

To avoid the stove being damaged during shipping, a ship-
ping bracket has been used and must be unbolted before
the stove can be installed.

1.

Remove the four nuts holding the shipping bracket to the

bottom of the stove.

2.

Lift the stove up and away from the skid to clear the

threaded bolts sticking through the bracket. Set down on a
flat surface. 

The stove top is not secured to the unit.

3.

 Discard the nuts, bracket and the skid.

FIGURE 1

THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED
BY A QUALIFIED INSTALLER

 to conform with local codes.

Installation practices vary from region to region and  it is important
to know the specifics that apply to your area,
for example: in Massachusetts State:

• The fireplace damper must be removed or welded in the open

position prior to installation of a fireplace insert or gas log.

• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or

bathroom unless the unit is a direct vent sealed combustion
product.

• WARNING: This product must be installed by a licensed plumber

or gas fitter when installed within the commonwealth of
Massachusetts.

In absence of local codes, install to the current CAN1-B149
Installation Code in Canada or to the National Fuel Gas Code,
ANSI Z223.1, and NFPA 54 in the United States. Mobile home
installation must conform with local codes. In the absence of
local codes, install to the current standard for gas equipped
mobile housing CAN/CSA Z240 MH Series in Canada or the
manufactured home construction and safety standard, Title 24
CFR, part 3280, or the Fire Safety Criteria for manufactured
home installations, Sites and Community Standard ANSI/NFPA
501A in the United States.

Purge all gas lines with the glass door of the stove removed.
Assure that a continuous gas flow is at the burner before re-
installing the door.
Under extreme vent configurations, allow several minutes (5-
15) for the flame to stabilize after ignition.
It is recommended that all horizontal runs have a ¼ inch rise
per foot.
Objects placed in front of the stove must be kept a minimum
of 48" away from the front face of the unit.

The stove and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psig (3.5 kPa). The
stove must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping  system at test pressures equal to
or less than ½ psig (3.5 kPa).
The stove, when installed with a blower, must be electrically
connected and grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1 CANADIAN
ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996
NATIONAL ELECTRICAL  CODE in the United States. The blower
power cord must be connected into a properly grounded receptacle.
The grounding prong must not be removed from the cord plug.

FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-
FIRED TO ASSURE ITS OPERATION AND QUALITY!

Minimum inlet gas supply pressure is 4.5 inches water column for
natural gas and 11 inches water column for propane. Maximum
inlet gas pressure is 7 inches water column for natural gas and 13
inches water column for propane. When the valve is set to "HI", the
manifold pressure under flow conditions is 3.5 inches water column
for natural gas and 10 inches water column for propane. When the
fireplace is installed at elevations above 4,500ft, and in the absence
of specific recommendations from the local authority having juris-
diction, the certified high altitude input rating shall be reduced at the
rate of 4% for each additional 1,000ft.

GENERAL INSTRUCTIONS

GENERAL INFORMATION

CARE OF GLASS, AND PLATED PARTS

SHIPPING BRACKET

Содержание CDCS600-P

Страница 1: ...ller service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOU...

Страница 2: ...he same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near...

Страница 3: ...orkmanship and material for life subject to the following conditions During the first 10 years WOLF STEEL Ltd will replace or repair the defective parts at our option free of charge From 10 years to l...

Страница 4: ...installation of a fireplace insert or gas log The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installati...

Страница 5: ...forsafeoperation Useafirestop when penetrating interior walls floor or ceiling Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the...

Страница 6: ...ertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carboning U...

Страница 7: ...7 W415 0162 E 03 05 04 FIGURE 8...

Страница 8: ...ns and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10 ft...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...aulking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield sh...

Страница 11: ...ent non combustible strapping to maintain the 1 clearance from combustibles FIGURE 23 FIGURE 24 This application occurs when venting through a roof Installation kits for vari ous roof pitches are avai...

Страница 12: ...the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Attach the other storm collar centered between the air intake and air exhaust slots onto th...

Страница 13: ...cept a standard matte black 7 stove pipe and the Con tinental decorative brass band standard with the GS 150KT Both are available from your Continental dealer Attach the B Vent label shown below in th...

Страница 14: ...r 1 2 type L copper tubing with a shut off valve to the stove 2 Seal and tighten the gas line securely to the flex connec tor DO NOT KINK FLEXIBLE CONNECTOR 3 Check for gas leaks by brushing on a soap...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...d at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermost...

Страница 17: ...ill quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a norm...

Страница 18: ...FF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all wi...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...ER 37 GD222 TERMINAL ASSEMBLY 38 BM67ADJ 30 TO 53 ADJUSTABLE PIPE 7 DIA 39 W500 0077 FIRESTOP WALL PLATE 40 W020 0032 HARDWARE 41 BRTC7 BRASS TRIM COLLAR 42 BM6724 24 STOVE PIPE 7 DIAMETER 43 W010 030...

Страница 21: ...21 W415 0162 E 03 05 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ing no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumper...

Страница 23: ...free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint or...

Страница 24: ...24 W415 0162 E 03 05 04...

Отзывы: