12
W415-0814 / A / 03.17.11
5.2.2 COUNTER TOP / BAR INSTALLATION
When fi nishing the appliance, combustible material
may rest directly on the top extension.
NOTE: Maximum weight tolerance is 400 lbs,
provided that it is evenly distributed across the
top extensions of the appliance.
In order to achieve a counter top or bar type ap-
pearance with the minimum height allowed, fram-
ing must be non-combustible and may be done
with metal studding attached to the top extension
sides or the upper frame of the appliance.
* The top extension may be removed if non-com-
bustible framing is faced with a non-combustible
material placed fl ush with the front face of the
appliance and extending from the top of the ap-
pliance. (Example: cement board) (not supplied).
Combustible counter / bar tops must maintain a
minimum of 38" from the base of the appliance to the
underside of the top.
NOTE: Wolf Steel trim and/or surround kits will
not totally cover the top extension of the ap-
pliance. In order to obtain a smooth transition
from the trim / surround to the wall, it is recom-
mended that the top extension be removed and
the appliance be installed following the above
procedure.
STUD
3"
NON-COMBUSTIBLE
MATERIAL
*METAL
3"
*COMBUSTIBLE
MATERIAL
EXTENSION
TOP
5½"
SEE FIGURE
BELOW
NON-COMBUSTIBLE
MATERIAL
COMBUSTIBLE
MATERIAL
TOP EXTENSION
TOP OF THE UNIT
5.2.3 BRICK PANEL INSTALLATION
RETAINER
DETAIL 5
STEP 3
STEP 2
STEP 1
STEP 4
STEP 5
Install the base panels as illustrated. The side panel sits under the bracket tab. Holding the side panel in posi-
tion, bend down the tab to secure.