background image

28

W415-0814 / A / 03.17.11

11.0 REPLACEMENTS

Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally 
all parts can be ordered through your Authorized dealer / distributor. 

FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE 
REQUIRED TO HONOUR THE CLAIM.

When ordering replacement parts always give the following information:
• 

Model & Serial Number of appliance

• 

Installation date of appliance

• Part 

number

• 

Description of part

• Finish

* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR 
FURTHER INFORMATION, CONTACT YOUR AUTHORIZED DEALER.

41.1

FAILURE TO POSITION THE PARTS 

IN ACCORDANCE WITH THIS 

MANUAL OR FAILURE TO USE ONLY 

PARTS SPECIFICALLY APPROVED 

WITH THIS APPLIANCE MAY 

RESULT IN PROPERTY DAMAGE OR 

PERSONAL INJURY.

!

WARNING

 COMMON COMPONENTS

REF NO.

OPEN-END

SEE-THRU

PENINSULA

ISLAND

DESCRIPTION

1*

W550-0001

W550-0001

W550-0001

W550-0001

CHARCOAL EMBERS 

2*

W562-0009

W562-0009

W562-0009

W562-0009

DOOR GASKET (100")

3

W010-0454

W010-0454

W010-0454

W010-0454

GLASS W/ GASKET

4*

W385-0430

W385-0430

W385-0430

W385-0430

CONTINENTAL® LOGO

5

GL-657

GL-657

GL-657

GL-657

LOG SET

6

W135-0284

W135-0284

W135-0284

W135-0284

LOG#1

7

W135-0285

W135-0285

W135-0285

W135-0285

LOG#2

8

W135-0286

W135-0286

W135-0286

W135-0286

LOG#3 - PIECE A

9

W135-0287

W135-0287

W135-0287

W135-0287

LOG#3 - PIECE B

10

W135-0288

W135-0288

W135-0288

W135-0288

LOG#4

11

W135-0289

W135-0289

W135-0289

W135-0289

LOG#5 - PIECE A

12

W135-0290

W135-0290

W135-0290

W135-0290

LOG#5 - PIECE B 

13

W475-0511

W475-0511

W475-0511

W475-0511

BRICK PANEL #1 - SANDSTONE

14

W475-0512

W475-0512

W475-0512

W475-0512

BRICK PANEL #2 - SANDSTONE

15

W475-0515

W475-0515

W475-0515

W475-0515

BRICK PANEL #4 - SANDSTONE

16

W475-0513

W475-0513

W475-0513

W475-0513

BRICK PANEL #3 - SANDSTONE

17*

W475-0514

W475-0514

W475-0514

W475-0514

SIDE BRICK PANEL -  SANDSTONE

18*

W080-0519

W080-0519

W080-0519

W080-0519

BOTTOM LOUVRE BRACKET

19*

W565-0041

W565-0041

W565-0041

W565-0041

SIDE HINGE SCREEN

20

W200-0114

N/A

N/A

N/A

SIDE DOOR COVER 

21

N010-0327

N/A

N/A

N/A

SIDE DOOR HEAT SHIELD

22

W475-0517

N/A

N/A

N/A

SIDE BRICK PANEL - FOR WALL

23

N/A

N/A

W010-0516

N/A

SIDE DOOR C/W GLASS

24*

W565-0054

N/A

W565-0054

W565-0054

END HINGE SCREEN

25

N010-0323

N010-0323

N010-0323

N/A

END DOOR COVER

26

W585-0126

W585-0126

W585-0126

N/A

END DOOR HEAT SHIELD

27

W475-0516

W475-0516

N/A

N/A

END BRICK PANEL - FOR WALL

28

W300-0057

N/A

N/A

N/A

END DOOR TEMPERED GLASS ONLY 

29

W010-0873

N/A

W010-0873

W010-0873

END DOOR TEMPERED GLASS C/W GASKET

30

W500-0192

W500-0192

W500-0192

N/A

END BRICK PANEL RETAINER

31

L36K

L36K

L36K

L36K

LOUVRE KIT - UPPER & LOWER - BLACK

32

ELB40K

ELB40K

ELB40K

ELB40K

END LOUVRE KIT - BLACK

Содержание BCNV40-N

Страница 1: ...YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas sup...

Страница 2: ...13 5 3 1 INSTALLATION 13 5 3 2 BRICK PANEL INSTALLATION 14 5 3 3 FACING 14 5 3 4 FINISHING 14 5 4 SEE THRU 15 5 4 1 INSTALLATION 15 5 4 2 BRICK PANEL INSTALLATION 15 5 4 3 FACING 15 5 4 4 FINISHING 16...

Страница 3: ...RVIEW Door see DOOR INSTALLATION section Bricks see BRICK PANEL INSTALLATION section Louvres see LOUVRE INSTALLATION section End door see END DOOR INSTALLA TION section Vent see VENTING section Rating...

Страница 4: ...stened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the appliance This appliance is a vented gas fired appliance Do not burn wood or other material...

Страница 5: ...2 1 2 4 1 4 ELECTRICAL INLET GAS INLET 6 1 2 38 32 1 2 36 38 22 1 8 22 1 8 25 1 8 2 1 2 4 1 4 ELECTRICAL INLET GAS INLET 6 1 2 38 32 1 2 36 38 22 1 8 22 1 8 2 1 2 4 1 4 ELECTRICAL INLET GAS INLET 6 1...

Страница 6: ...u should choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material...

Страница 7: ...LES FLAMMESAUTRE QUE CELUI QUI EST FOURNIAVEC CETAPPAREIL PAR LE FABRICANT THEAPPLIANCE MUST BE VENTED USING B VENT SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS L APPAREIL DOIT EVACUER SES GAZ...

Страница 8: ...ve control area may be attached to a wall switch or thermostat TAMPERING WITH THE SAFETY SWITCH CAN RESULT IN CARBON MONOXIDE POISONING AND POSSIBLE DEATH WARNING PLUNGER A HI LIMIT SWITCH B This is a...

Страница 9: ...moke is still not drawn into the draft hood turn the appliance off and check for vent blockage or restriction If necessary consult with a qualified inspector The Vent Safety or Hi Limit switches must...

Страница 10: ...uld be installed to provide sufficient movement for shifting the burner assembly on it s side to aid with servicing components F Check for gas leaks by brushing on a soap and water solution WARNING RI...

Страница 11: ...MATERIALS CONSISTING ENTIRELY OF STEEL IRON BRICK TILE CONCRETE SLATE GLASS OR PLASTERS OR ANY COMBINATION THEREOF ARE SUITABLE MATERIALS THAT ARE REPORTED AS PASSING ASTM E 136 STANDARD TEST METHOD...

Страница 12: ...rom the top of the ap pliance Example cement board not supplied Combustible counter bar tops must maintain a minimum of 38 from the base of the appliance to the underside of the top NOTE Wolf Steel tr...

Страница 13: ...llation of many decorative flashing acces sories Objects placed in front of the appliance should be kept a minimum of 48 away from the glass front face DRYWALL DRYWALL 4 MIN Refer to FINISHING section...

Страница 14: ...anned for will interfere with the opening of the lower access door and the installation of many decorative flashing accessories Objects placed in front of the appliance should be kept a minimum of 48...

Страница 15: ...Combustible materials may be installed flush with the front of the appliance but must not cover any of the black face areas of the appliance Non combustible material brick stone or ceramic tile may p...

Страница 16: ...and frame to local building codes A 221 8 minus finishing material thickness each side B 36 minus finishing material thickness each end To install the appliance face flush with the finished wall posit...

Страница 17: ...ing in the appliance raise the appliance to accommodate for the thickness of the finished floor materials i e tile carpeting hard wood which if not planned for will interfere with the opening of the l...

Страница 18: ...s when a non combustible facing is used MANTEL WIDTH H E I H T M A N T E L COMBUSTIBLE MATERIALS 7 MANTLE TOP OF UNIT 3 MANTLE TOP OF THE UNIT TOP EXTENTION 7 3 WARNING RISK OF FIRE MAINTAIN ALL SPECI...

Страница 19: ...DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED FACING AND OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH A...

Страница 20: ...sits on top of log 1 inside the groove on log 2 D Log 3 is made up of two pieces a and b Piece 3a is the base of log 3 The base sits diagonally in the designated area located between logs 1 and fits...

Страница 21: ...lded locator on the top of log 1 Log colours may vary During the initial use of the appliance the colours will become more uniform as colour pigments burn in during the heat activated curing process P...

Страница 22: ...ON NOTE This blower is not suitable for the 4 sided island installation WARNING RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF ST...

Страница 23: ...he bracket from the top right side of the firebox Remove the thermal switch from the bracket supplied in the blower kit and install the thermal switch into the bracket removed from the firebox top The...

Страница 24: ...ot burner to be lit until the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless...

Страница 25: ...heck that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 3 P I P I L O T N O L O T HI L O F F O A B PILOT SCREW PILOT BURNE...

Страница 26: ...e area surrounding the logs clean by vacuuming or brushing at least once a year 3 Check to see that all burner ports are burning Clean out any of the ports which may not be burning or are not burning...

Страница 27: ...equipped with plated parts you must clean fingerprints or other marks from the plated surfaces before operating the appliance for the first time Use a glass cleaner or vinegar and towel to clean If no...

Страница 28: ...35 0286 W135 0286 W135 0286 W135 0286 LOG 3 PIECE A 9 W135 0287 W135 0287 W135 0287 W135 0287 LOG 3 PIECE B 10 W135 0288 W135 0288 W135 0288 W135 0288 LOG 4 11 W135 0289 W135 0289 W135 0289 W135 0289...

Страница 29: ...068 W455 0068 W455 0068 W455 0068 PROPANE GAS PILOT INJECTOR 37 W660 0005 W660 0005 W660 0005 W660 0005 BURNER ON OFF SWITCH 38 W680 0004 W680 0004 W680 0004 W680 0004 THERMOPILE 39 W680 0005 W680 000...

Страница 30: ...30 W415 0814 A 03 17 11 21 22 26 29 27 41 5 7 8 9 6 10 11 12 25 13 15 16 28 3 23 30 20 42 33 36 39 38 35 14 39 43 34 32 31...

Страница 31: ...TS BLACK 3 COISS CONTINENTAL ORNAMENTAL INSETS SATIN CHROME 4 ECOIK END HERITAGE ORNAMENTAL INSET GOLD PLATED 4 ECOISS END HERITAGE ORNAMENTAL INSET BLACK GOLD PLATED 5 GD825N VALVE REGULATOR FOR W660...

Страница 32: ...nob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace switch thermostat Wall switch wiring is...

Страница 33: ...re increase fresh air supply Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensure air shutter opening is free of lint or other obstructions Flam...

Страница 34: ...ns such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be ca...