Maintenance
7-14
To replace the lamp-unit:
The lamp cover is on the right side of the scanner.
Grasp the cover on both sides, pull back and then
up to detach.
Free the cover from the scanner. Pull out the lamp-unit
and insert the new one.
7.4.4 Replacing the Dust-Filters
Fresh dust filters can reduce the amount of time spent on cleaning and calibration. The dust
filters protect your scanner’s air-cooling vents. Some scanner models are designed so users
can replace the dust filters. On other models, a service technician must perform this process.
See your scanner’s model specifications to see if the dust filters are user-replaceable on your
scanner. WIDEsystem monitors usage and will warn you when it is time for a replacement.
Replacing the Dust-filters:
On Scanners
:
1.
Turn the scanner power off and disconnect the power plug.
2. Locate the 2 square-shaped dust filter bins on the underside of the scanner.
3. Pull down on the edge of a dust filter bin to detach it from its frame.
4. The filter (soft material) is inside the bin. Remove the old filter and replace with a fresh
one.
5. Reattach (click on) the bin to its frame on the underside of the scanner.
6. Repeat the process with the second filter.