6 Setting the Touch panel Driver
PT-E731, PT-E731S, PT-E731H, PT-E731HS User’s Manual
57
(3) Calibration points
Specify the number of calibration points to be set.
The default is “4” points. For revising a position difference correctly, increase the number of the
calibration points.
-
The setting range 2 to 25 points
(4) Timeout
Indicate the calibration timeout value if the calibration point is not touched within the specified
period. Defined it in seconds.
The default is “10” seconds.
-
The setting range 10 to 60 seconds
(5) Starting
Set the position of the calibration point.
On 4 corners of the screen, it is 0%. The bigger the setting value is, the nearer the screen center
position calibration point becomes.
The default is set to “5%”.
(6) Transparent Background
If it is enabled, specify that the calibration points are shown on the Windows desktop without a white
background.
(7) EEPROM Calibration
Set where the calibration setting data are saved.
-
If enabled, save the calibration setting data in EEPROM.
-
If disabled, save the calibration data in the windows.
When using EEPROM calibration, the position (position of the arrow) of the calibration point
becomes a fixation.
*: About calibration setting method, refer to following.
-
Save to Windows
Refer to p. 45.
-
Save to EEPROM
Refer to p. 45.
(8) Calibration Pattern
Show the calibration point pattern to be set in (3) and (5).
Used to confirm the number of points and point position that have been set in (3) and (5).