6 Setting the Touch panel Driver
60
PT-E731, PT-E731S, PT-E731H, PT-E731HS User’s Manual
Action Settings
Used to adjust the reaction time or the touch action when touching a touch panel.
(7)
(1)
(2)
(3)
(4)
(5)
(6)
Figure 6.19 Settings tab
(1) Click time
Click time is “a short time” interval that the driver uses in the button click logic that uses time
intervals between clicks.
(2) Tap time
Tap time is “a short time” interval that the driver uses in the button click logic that uses time intervals
between taps.
(3) Lift off time
The Lift off Time value specifies the time interval required to register a stylus lift. Lift off time is
defined in units of 20ms. This value is only used to perform a pen up if the ‘Use Lift off’ packet is
disabled otherwise Pen ups are generated as soon as the stylus leaves the pointer device display.
(4) Stabilization
Stabilization causes small movements to be ignored.
(5) Averaging
Apply a filter to produce smoother drawing. Averaging takes the average of the last N co-ordinates.
This is a very basic approach to filtering that can improve drawing and not affect drawing speed.
(6) Use lift off pocket
If enabled, when click the screen, it assumes separated immediately when separating a finger.
When input characters, don’t check the checkbox.
(7) [Default (U)] button
Press the [Default (U)] button to return to the default setting.
Содержание PT-E731
Страница 1: ...IPC Series PANEL PC E Series PT E731 PT E731S PT E731H PT E731HS User s Manual CONTEC CO LTD...
Страница 7: ...1 Introduction vi PT E731 PT E731S PT E731H PT E731HS User s Manual...
Страница 67: ...6 Setting the Touch panel Driver 66 PT E731 PT E731S PT E731H PT E731HS User s Manual...